Installation and commissioning Technical data Hazardous location label Laser safety compliance Repair and maintenance Applied standards and guidelines III. Product Specifications PSCAN-D-1D-D2 function Best reading angles Reading characteristics PSCAN and connector dimensions General specifications, Accessories IV. Installation Preparation Installation wiring...
NO WARRANTY IS PROVIDED FOR THE ACCURACY OF THE INFORMATION CONTAINED IN THIS MANUAL. AS MISTAKES CANNOT BE ENTIRELY AVOIDED The PSCAN-D-1D-D2 EX barcode reader can be used in Class I/Div. 2, DESPITE TAKING THE GREATEST OF CARE, WE WOULD BE GRATEFUL TO Class II/Div.
PSCAN-D-1D-D2 Division 2 Barcode Reader Product specifications Laser safety compliance The barcode reader conforms to the following applicable requirements at PSCAN-D-1D-D2 function the date of manufacture: • EN 60825-1 The PSCAN-D-1D-D2EX barcode reader can be used in Class I/Div. 2 and •...
PSCAN-D-1D-D2 Division 2 Barcode Reader Reading characteristics PSCAN-D-1D-D2-20-10-N Reading characteristics General specifications Read field width in cm Read field width in mm Readable codes 2/5 Family, Code 39, (plus Code 32, Clip 39), EAN/UPC, EAN 128, Code 128, Code 93,...
Page 6
M12 connector, male 4-pin Female 4-pin receptacle 67.5 Replacement connection cable The PSCAN-D-1D-D2 connecting cable is a cable for replacement for the barcode reader PSCAN-D-1D-D2. The mounting instructions are found in the Maintenance and Repair section on page 80. Connector RJ45...
When connecting the barcode reader wiring to the SK-PC-D2 long tones nonvolatile memory nonincendive barrier, please follow the tables below. The color coding is based on the Pepperl+Fuchs cable accessories that are sold with the HLHL Hardware error in EEPROM PSCAN-D-1D-D2.
PSCAN-D-1D-D2 Division 2 Barcode Reader Mounting the holder for the barcode reader Holder for the barcode reader, top view Edge protection Distance plate M3 washer M3 lock washer Hex nut Gasket Hole pattern holder for the barcode reader Adapter (bracket)
PSCAN-D-1D-D2 Division 2 Barcode Reader Configuration To configure your reader: 1) Open the folded page in manual with the hex-numeric table and keep it open during the device configuration. Reading configuration barcodes 2) Read the Enter Configuration code ONCE. This manual can be used for complete setup and configuration of your 3) Modify the desired parameters in one or more sections following the reader by following the setup procedures in this chapter.
PSCAN-D-1D-D2 Division 2 Barcode Reader USB reader configuration Changing default settings The USB interface is available for the PScan-D-1D-D2 device and is Once your reader is set up, you can change the default parameters to compatible with the following Operating Systems: meet your application needs.
Page 13
PSCAN-D-1D-D2 Division 2 Barcode Reader Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î RS-232 DATA BITS 7 bits ÌCA0OÎ 8 bits ÌCA1RÎ 9 bits ÌCA2UÎ STOP BITS 1 stop bit ÌCB0QÎ 2 stop bits ÌCB1TÎ HANDSHAKING disable ÌCE0WÎ...
Page 14
PSCAN-D-1D-D2 Division 2 Barcode Reader Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î RS-232 ACK/NACK PROTOCOL disable ÌER0sÎ enable ÌER1vÎ ® See par. 5.1.2 for details, particularly on implementing this parameter with PowerScan M8300. FIFO disable ÌEC0UÎ enable ÌEC1XÎ...
Page 15
PSCAN-D-1D-D2 Division 2 Barcode Reader Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î RS-232 RX TIMEOUT timeout control in reception from Host ÌCL5Î Read 2 numbers from the table where: 00 = TIMEOUT disabled 01-99 = TIMEOUT from .1 to 9.9 seconds ...
PSCAN-D-1D-D2 Division 2 Barcode Reader USB Parameters USB-IBM USB-COM • • No parameter selection required Handshaking • Ack/Nack protocol 1. Read the Enter Configuration code ONCE. • FIFO • 2. Read configuration codes from the desired groups. Inter-character delay •...
Page 17
PSCAN-D-1D-D2 Division 2 Barcode Reader Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î USB-COM INTER-CHARACTER DELAY delay between characters transmitted to Host ÌCK3Î Read 2 numbers from the table where: 00 = DELAY disabled 01-99 = DELAY from 1 to 99 milliseconds ...
Page 18
PSCAN-D-1D-D2 Division 2 Barcode Reader Exit and Save Configuration NTER ONFIGURATION Ì$+;Î Ì$-?Î USB-KBD KEYBOARD NATIONALITY Not Available for USB-KBD-ALT-MODE Interface This parameter default value is restored through the Interface Selection code and not Restore Default. Belgian ÌFJ7yÎ English (UK) ÌFJ4pÎ...
Page 19
PSCAN-D-1D-D2 Division 2 Barcode Reader Exit and Save Configuration NTER ONFIGURATION Ì$+;Î Ì$-?Î USB-KBD The Japanese and Eastern Block Keyboard Nationality selections are valid only for IBM AT compatible PCs. Japanese ÌFJ8|Î Russian (Latin) ÌFJ9ÃÎ Russian (Cyrillic) ÌFJA0Î Hungarian ÌFJB3Î...
Page 20
PSCAN-D-1D-D2 Division 2 Barcode Reader Exit and Save Configuration NTER ONFIGURATION Ì$+;Î Ì$-?Î USB-KBD INTER-CHARACTER DELAY delay between characters transmitted to Host ÌCK3Î Read 2 numbers from the table where: 00 = DELAY disabled 01-99 = DELAY from 1 to 99 milliseconds ...
PSCAN-D-1D-D2 Division 2 Barcode Reader Data format Default code selection Parameter Default • EAN /UPC - family EAN 8/EAN 13 / UPC A/UPC E Code identifier • Check digit control Custom code identifier No conversion • Header 2/5 family Interleaved 2/5 •...
Page 22
PSCAN-D-1D-D2 Division 2 Barcode Reader Reference Code identifier AIM standard identifiers are not defined for all codes: the X identifier is Code Datalogic Custom assigned to the code for which the standard is not defined. The y value standard standard...
Page 23
PSCAN-D-1D-D2 Division 2 Barcode Reader Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î DATA FORMAT CODE IDENTIFIER disable ÌEB0SÎ Datalogic standard ÌEB1VÎ AIM standard ÌEB2YÎ custom ÌEB3\Î CUSTOM CODE IDENTIFIER define custom code identifier(s) ÌEH/Î Read the above code.
Page 24
PSCAN-D-1D-D2 Division 2 Barcode Reader Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î DATA FORMAT HEADER no header ÌEA00*Î one character header ÌEA01.Î two character header ÌEA022Î three character header ÌEA036Î four character header ÌEA04:Î ...
Page 25
PSCAN-D-1D-D2 Division 2 Barcode Reader Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î DATA FORMAT TERMINATOR no terminator ÌEA10-Î one character terminator ÌEA111Î two character terminator ÌEA125Î three character terminator ÌEA139Î four character terminator ÌEA14=Î five character terminator ÌEA15AÎ...
Page 26
PSCAN-D-1D-D2 Division 2 Barcode Reader Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î DATA FORMAT FIELD ADJUSTMENT disable field adjustment ÌEF0[Î Field adjustment allows a number of characters n, to be added to or subtracted from the barcode read. The adjustment can be different for each enabled code type. To define the field adjustment: ...
Page 27
PSCAN-D-1D-D2 Division 2 Barcode Reader Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î DATA FORMAT FIELD ADJUSTMENT CHARACTER Read the field adjustment character code: field adjustment character ÌEG-Î Read the hexadecimal value corresponding to the character you want to use for field adjustment.
Page 28
PSCAN-D-1D-D2 Division 2 Barcode Reader Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î DATA FORMAT CHARACTER REPLACEMENT disable character replacement ÌEO0mÎ This parameter allows up to three characters to be replaced from the barcode read. These substitutions are stored in memory. To define each character replacement: ...
Page 29
PSCAN-D-1D-D2 Division 2 Barcode Reader Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î DATA FORMAT Example: The following strings define: First Character Replacement: substitution in Code 39 barcodes of all occurrences of the 0 character with the 1 character. Second Character Replacement: substitution in Code 39 barcodes of all occurrences of the A character with the B character.
PSCAN-D-1D-D2 Division 2 Barcode Reader Reading parameters • Trigger type 1. Read the Enter Configuration code ONCE. • Trigger signal 2. Read configuration codes from the desired groups. • Trigger click • • Read the code and follow the procedure given...
Page 31
PSCAN-D-1D-D2 Division 2 Barcode Reader Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î READING PARAMETERS TRIGGER-OFF TIMEOUT trigger-off timeout ÌBD$Î Read 2 numbers in the range 00-99: 00 = disables the trigger-off timeout 01-99 = corresponds to a max. 99-sec. delay after the trigger press to allow the reader to turn off automatically.
Page 32
PSCAN-D-1D-D2 Division 2 Barcode Reader Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î READING PARAMETERS SAFETY TIME safety time ÌBE&Î Limits same code consecutive reading. Read 2 numbers in the range 00-99: 00 = no same code consecutive reading until reader is removed (no decoding) for at least 400 ms.
Page 33
PSCAN-D-1D-D2 Division 2 Barcode Reader Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î READING PARAMETERS BEEPER TONE tone 1 ÌBH0\Î tone 2 ÌBH1_Î tone 3 ÌBH2bÎ tone 4 ÌBH3eÎ BEEPER TYPE monotone ÌBJ0`Î bitonal ÌBJ1cÎ BEEPER LENGTH long ÌBI0^Î...
Page 34
PSCAN-D-1D-D2 Division 2 Barcode Reader Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î READING PARAMETERS GOOD READ SPOT DURATION disable ÌBV0xÎ short ÌBV1{Î medium ÌBV2~Î long ÌBV3ÅÎ AIMING SYSTEM disabled ÌBj09Î enabled ÌBj1<Î CRADLE BEEPER INTENSITY disable ÌJI0fÎ...
PSCAN-D-1D-D2 Division 2 Barcode Reader Decoding parameters Before changing these parameter values, be aware that these parameters are intended to enhance the decoding capability of the reader for particular applications. Used • incorrectly, they can degrade the reading performance or...
PSCAN-D-1D-D2 Division 2 Barcode Reader Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î DECODING PARAMETERS DECODING SAFETY one read ÌED0WÎ (decoding safety disabled) two reads ÌED1ZÎ three reads ÌED2]Î four reads ÌED3`Î Required number of good reads before accepting code.
PSCAN-D-1D-D2 Division 2 Barcode Reader Code selection Code selections may be performed according to two different procedures: • Auto-configuration • Auto configuration, allowing an automatic recognition and selection • EAN/UPC family of the code families to be read; • 2/5 family •...
Page 38
PSCAN-D-1D-D2 Division 2 Barcode Reader Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î CODE SELECTION Enter Configuration Exit and Save Configuration DISABLE ALL CODE FAMILIES Ì$+;Î Ì$-?Î CODE SELECTION ÌAZ0ÃÎ SELECT EAN/UPC PREFIXES When scanning the following codes, barcodes starting with the selected The reader allows up to 10 code selections.
Page 39
PSCAN-D-1D-D2 Division 2 Barcode Reader Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î CODE SELECTION EAN/UPC FAMILY disable the family ÌAA0MÎ Read the desired family code NOTE: Since the EAN/UPC without ADD ON code selection is enabled by default, to correctly enable another selection, first disable the family.
Page 40
PSCAN-D-1D-D2 Division 2 Barcode Reader Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î CODE SELECTION WITH ADD ON 2 ONLY EAN 8/EAN 13 ÌAAK7Î UPC A/UPC E ÌAAM=Î WITH ADD ON 5 ONLY EAN 8/EAN 13 ÌAAL:Î UPC A/UPC E ÌAAN@Î...
Page 41
PSCAN-D-1D-D2 Division 2 Barcode Reader Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î CODE SELECTION SELECT EAN/UPC PREFIXES When scanning the following codes, barcodes starting with the selected prefixes will be read and transmitted only if the ADD ON is present. If no ADD ON is found, the barcode will not be read.
Page 42
PSCAN-D-1D-D2 Division 2 Barcode Reader Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î CODE SELECTION Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î CODE SELECTION Example: Example: The following string allows reading and transmitting with ADD ON all EAN/UPC starting with the...
Page 43
PSCAN-D-1D-D2 Division 2 Barcode Reader Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î CODE SELECTION EAN/UPC CHECK DIGIT TX SELECTIONS For each code type in this family you can choose to transmit the check digit or not CHECK DIGIT TRANSMISSION...
Page 44
PSCAN-D-1D-D2 Division 2 Barcode Reader Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î CODE SELECTION CONVERSION OPTIONS UPC E to UPC A conversion ÌAAAÄÎ UPC E to EAN 13 conversion ÌAABÇÎ UPC A to EAN 13 conversion ÌAACÊÎ EAN 8 to EAN 13 conversion ÌAAD"Î...
Page 45
PSCAN-D-1D-D2 Division 2 Barcode Reader Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î CODE SELECTION 2/5 FAMILY disable the family ÌAC0QÎ Read the desired family code Read a check digit selection Interleaved 2/5 ÌAC1TÎ CHECK DIGIT TABLE no check digit control Ì12Î...
Page 46
PSCAN-D-1D-D2 Division 2 Barcode Reader Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î CODE SELECTION CODE 39 FAMILY disables the family ÌAB0OÎ Read the desired family code Read a check digit selection CHECK DIGIT TABLE Standard Code 39 ...
Page 47
PSCAN-D-1D-D2 Division 2 Barcode Reader Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î CODE SELECTION CODE 128 FAMILY disable the family ÌAI0]Î Read the desired family code Code 128 ÌAI11=Î control without transmission of ISBT 128 check digit ÌAI31CÎ...
Page 48
PSCAN-D-1D-D2 Division 2 Barcode Reader Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î CODE SELECTION CODE 93 disable the code ÌAK0aÎ Code 93 ÌAK1dÎ control without transmission of check digit CODABAR FAMILY disable the family ÌAD0SÎ Read the desired equality control code ...
Page 49
PSCAN-D-1D-D2 Division 2 Barcode Reader Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î CODE SELECTION The Codabar ABC code below uses a fixed start/stop character transmission selection. Codabar ABC ÌAD212)Î no start/stop character equality control but transmission. Codabar ABC Forced Concatenation enable Codabar ABC with forced concatenation ÌAD2321Î...
Page 50
PSCAN-D-1D-D2 Division 2 Barcode Reader Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î CODE SELECTION disable the family ÌAE0UÎ Enable the code by selecting one of the check digit selections. no check digit control ÌAE1XÎ MOD10 check digit control no check digit transmission ÌAE2[Î...
Page 51
PSCAN-D-1D-D2 Division 2 Barcode Reader Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î CODE SELECTION CODE 11 disable the family ÌAG0YÎ Enable the code by selecting one of the check digit selections. no check digit control ÌAG1\Î Type C check digit control check digit transmitted ÌAG21<Î...
Page 52
PSCAN-D-1D-D2 Division 2 Barcode Reader Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î CODE SELECTION CODE 16K disable the code ÌAJ0_Î Code 16K ÌAJ1bÎ To read stacked codes, simply move the reader over the code so that each line of the code is scanned.
Page 53
PSCAN-D-1D-D2 Division 2 Barcode Reader Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î CODE SELECTION GS1 DATABAR™ CODES disable the family ÌAQ0mÎ DISABLE CODE ENABLE CODE disable GS1 DataBar Expanded Linear and Stacked ÌAQ10IÎ enable GS1 DataBar Expanded Linear and Stacked ÌAQ11MÎ...
PSCAN-D-1D-D2 Division 2 Barcode Reader Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î Advanced formatting CODE SELECTION • 1. Read the Enter Configuration code ONCE. Concatenation SELECT EAN/UPC PREFIXES • 2. Read configuration codes from the desired groups. Advanced formatting •...
Page 55
PSCAN-D-1D-D2 Division 2 Barcode Reader Exit and Save Configuration Ì$-?Î ADVANCED FORMATTING Code 2 code ID ÌEK1hÎ , page 75. Read the code type from the Code Identifier Table beginning in Appendix code length ÌEL1jÎ Read a number in the range 01-99 from the Hex/Numeric Table.
Page 56
PSCAN-D-1D-D2 Division 2 Barcode Reader Exit and Save Configuration Ì$-?Î ADVANCED FORMATTING Transmission after Timeout no code transmitted after timeout ÌEM0iÎ only code 1 transmitted (if read) after timeout ÌEM1lÎ only code 2 transmitted (if read) after timeout ÌEM2oÎ either code 1 or code 2 transmitted after timeout ÌEM3rÎ...
Page 57
PSCAN-D-1D-D2 Division 2 Barcode Reader ADVANCED FORMATTING ADVANCED FORMATTING Advanced formatting has been designed to offer you complete flexibility in changing the format of barcode data before transmitting it to the host system. This formatting will be performed when the barcode data meets certain criteria, which you will define in the following procedure.
Page 58
PSCAN-D-1D-D2 Division 2 Barcode Reader Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î ADVANCED FORMATTING Begin Format Definition begin Format 1 definition ÌHA0TÎ begin Format 2 definition ÌHA1WÎ begin Format 3 definition ÌHA2ZÎ begin Format 4 definition ÌHA3]Î...
Page 59
PSCAN-D-1D-D2 Division 2 Barcode Reader Exit and Save Configuration Ì$-?Î ADVANCED FORMATTING Match with Predefined Characters no match ÌHD0HE00ÄÎ match with 1 character ÌHD1]Î match with a 2-character string ÌHD2`Î match with a 3-character string ÌHD3cÎ match with a 4-character string ÌHD4fÎ...
Page 60
PSCAN-D-1D-D2 Division 2 Barcode Reader Exit and Save Configuration Ì$-?Î ADVANCED FORMATTING Divide Code into Fields divide code into fields ÌHF.Î Read one number in the range 1 to 5 to divide the code into fields. Define Code Fields...
Page 61
PSCAN-D-1D-D2 Division 2 Barcode Reader Exit and Save Configuration Ì$-?Î ADVANCED FORMATTING DEFINE FIELD 1 BY: EITHER field separator ÌHG0`Î Read the field separator character from the HEX table. Range of characters = 00-FE. discard separator include separator Ì01Î...
Page 62
PSCAN-D-1D-D2 Division 2 Barcode Reader Exit and Save Configuration Ì$-?Î ADVANCED FORMATTING DEFINE FIELD 2 BY: EITHER field separator ÌHG0`Î Read the field separator character from the HEX table. Range of characters = 00-FE. discard separator include separator Ì01Î...
Page 63
PSCAN-D-1D-D2 Division 2 Barcode Reader Exit and Save Configuration Ì$-?Î ADVANCED FORMATTING DEFINE FIELD 3 BY: EITHER field separator ÌHG0`Î Read the field separator character from the HEX table. Range of characters = 00-FE. discard separator include separator Ì01Î...
Page 64
PSCAN-D-1D-D2 Division 2 Barcode Reader Exit and Save Configuration Ì$-?Î ADVANCED FORMATTING DEFINE FIELD 4 BY: EITHER field separator ÌHG0`Î Read the field separator character from the HEX table. Range of characters = 00-FE. discard separator include separator Ì01Î...
Page 65
PSCAN-D-1D-D2 Division 2 Barcode Reader Exit and Save Configuration Ì$-?Î ADVANCED FORMATTING DEFINE FIELD 5 BY: EITHER field separator ÌHG0`Î Read the field separator character from the HEX table. Range of characters = 00-FE. discard separator include separator Ì01Î...
Page 66
PSCAN-D-1D-D2 Division 2 Barcode Reader Exit and Save Configuration Ì$-?Î ADVANCED FORMATTING First Additional Fixed Field no fixed field ÌHI0dÎ 1 character fixed field ÌHI1gÎ 2 character fixed field ÌHI2jÎ 3 character fixed field ÌHI3mÎ 4 character fixed field ÌHI4pÎ...
Page 67
PSCAN-D-1D-D2 Division 2 Barcode Reader Exit and Save Configuration Ì$-?Î ADVANCED FORMATTING Second Additional Fixed Field no fixed field ÌHJ0fÎ 1 character fixed field ÌHJ1iÎ 2 character fixed field ÌHJ2lÎ 3 character fixed field ÌHJ3oÎ 4 character fixed field ÌHJ4rÎ...
Page 68
PSCAN-D-1D-D2 Division 2 Barcode Reader Exit and Save Configuration Ì$-?Î ADVANCED FORMATTING Field Transmission number of fields to transmit ÌHK8Î Read one number in the range 1 to 7 for the number of fields to transmit. Include only fields to be transmitted.
Page 69
PSCAN-D-1D-D2 Division 2 Barcode Reader Exit and Save Configuration Ì$-?Î ADVANCED FORMATTING Standard Formatting do not apply standard formatting ÌHL0jÎ apply standard formatting ÌHL1mÎ ® POWERSCAN D8330: After performing Advanced Formatting on the barcode read, Standard PSCAN-D-1D-D2: Formatting (Headers, Code Length, Code ID, Terminators) can be applied to the message to be transmitted.
Page 70
PSCAN-D-1D-D2 Division 2 Barcode Reader Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î ADVANCED FORMATTING Enable Advanced Format no Advanced Formats enabled ÌHN0nÎ Advanced Format 1 enable ÌHN11NÎ disable ÌHN10JÎ Advanced Format 2 enable ÌHN21QÎ disable ÌHN20MÎ Advanced Format 3 enable ÌHN31TÎ...
Page 71
PSCAN-D-1D-D2 Division 2 Barcode Reader Enter Configuration Exit and Save Configuration Ì$+;Î Ì$-?Î ADVANCED FORMATTING No Match Result clear data - no transmission ÌHO0pÎ transmit data using standard format ÌHO1sÎ This selection determines the action to be taken when codes read do not conform to the advanced format requisites (no match).
PSCAN-D-1D-D2 Division 2 Barcode Reader References Reads per cycle In general, a reading cycle corresponds to the ON + OFF times of a device. The resulting effects of this parameter on code reading depend on other ACK/NACK protocol related configuration conditions. Here are the definitions of ON and OFF REFERENCES times.
Ì$+$1$Î PSCAN-D-1D-D2 Division 2 Barcode Reader 5.13 CODE TYPE RECOGNITION Advanced formatting Code type recognition This procedure allows the reader to enter a particular state during which it reads transmits to the Host information about the family type of codes unknown to the...
PSCAN-D-1D-D2 Division 2 Barcode Reader Message formatting Font Selection ESC [ 0 m Normal mode The system always provides PSCAN-D (barcode reader) to host data communication using the following message formatting: ESC [ 7 m Reverse mode [Header][Barcode reader-Address] ESC # 4...
Codes and Character Sets PSCAN-D-1D-D2 Division 2 Barcode Reader Codes and Character Sets Codes and character sets Single codes Single codes • To enter numerical values, scan successively the digits 0-9. • To enter numerical values, scan successively the digits 0-9.
Page 76
PSCAN-D-1D-D2 Division 2 Barcode Reader POWERSCAN Codes and character sets (cont.) Codes and Character Sets Code Identifier Table 2/5 Interleaved 2/5 Industrial 2/% normal 5 bars 2/5 matrix 3 bars EAN 8 EAN 13 UPC A UPC E Subject to modifications www.pepperl-fuchs.us...
PSCAN-D-1D-D2 Division 2 Barcode Reader Code identifier table Code Identifier Table 2/5 Interleaved 2/5 Industrial 2/% normal 5 bars 2/5 matrix 3 bars EAN 8 EAN 13 UPC A UPC E EAN 8 mit 2 ADD ON with EAN 8 mit 5 ADD ON...
Page 78
PSCAN-D-1D-D2 Division 2 Barcode Reader POWERSCAN Codes and Character Sets Code identifier table (cont.) with with EAN 13 mit 2 ADD ON EAN 13 mit 5 ADD ON UPC A mit 2 ADD ON with UPC A mit 5 ADD ON...
PSCAN-D-1D-D2 Division 2 Barcode Reader POWERSCAN Codes and Character Sets Hex and numeric tables ASCII control characters Decimal Hexadecimal Character Meaning of the most important Control characters 00 h without effect 01 h Start of header 02 h Start of text...
Page 81
PSCAN-D-1D-D2 Division 2 Barcode Reader POWERSCAN Codes and Character Sets Hex and numeric tables (cont) Hexa- Hexa- Hexa- Decimal decimal Character Decimal decimal Character Decimal decimal Character 20 h SPACE 40 h 60 h 21 h 41 h 61 h...
3. First, slide down the strain relief and then the cover over the yellow "tooth." Slide down the cable spacer. Repair If repair is needed, please contact your local Pepperl+Fuchs office. Installation cable "Cable PSCAN-D-1D-D2" to barcode reader PSCAN-D-* Exchange of the cable on barcode reader PSCAN-D-1D-D2 Scope of supply 4.
Page 83
PSCAN-D-1D-D2 Division 2 Barcode Reader Install the new cable on the barcode reader 5. Insert the cable with the plastic boot (2) and gasket (1) into the handle. Ensure that the "FRONT" marking on the plastic boot (2) is facing 1.
Page 84
PSCAN-D-1D-D2 Division 2 Barcode Reader 7. Push the cover (4) along the cable toward the reader, and hook it over the yellow "tooth." 8. Insert the strain relief (5) into the cover (4) and tighten the screw to fix the whole assembly to the reader handle.
Need help?
Do you have a question about the PSCAN-D-1D-D2 and is the answer not in the manual?
Questions and answers