Pepperl+Fuchs VB14N Manual page 52

Host mode programming
Hide thumbs Also See for VB14N:
Table of Contents

Advertisement

HOST MODE PROGRAMMING
PARAMETER
Main Port Electrical
Interface
MUX 32 protocol
address
Handshake
(RS232)
Handshake
(RS485)
Baud Rate (Mux32
Slave)
Baud Rate (NOT
Mux32 Slave)
Parity
Data Bits
Stop Bits
Checksum
(Siemens 3964)
Priority
(Siemens 3964)
Header n. 5
(Siemens 3964)
50
COMPLETE PATH
/Comms
/SerMain/Line
/MainHW
/Comms
/SerMain/Line
/Addr
/Comms
/SerMain/Line
/FlowCtrl
/Comms
/SerMain/Line
/Flow485
/Comms
/SerMain/Line
/StdBaud
/Comms
/SerMain/Line
/MuxBaud
/Comms
/SerMain/Line
/Parity
/Comms
/SerMain/Line/Data
/Comms
/SerMain/Line/Stop
/Comms
/SerMain/Line
/S3964Chk
/Comms
/SerMain/Line
/S3964Prio
/Comms
/SerMain/Line
/SRKHead5
SHC PT
VALUE
10
1
0 = RS232
1 = RS485 Full Duplex
58
0
Range: 0 to 31
57
1
0 = None
1 = Hardware (RTS/CTS)
2 = Software (Xon/Xoff)
60
1
0 = None
1 = Software (Xon/Xoff)
49
1
8 = 1200
1 = 2400
2 = 4800
3 = 9600
4 = 19200
5 = 38400
6 = 57600
7 = 115200
59
1
1 = 2400
2 = 4800
3 = 9600
4 = 19200
5 = 38400
6 = 57600
50
1
0 = None
1 = Odd
2 = Even
51
1
0 = 7
1 = 8
52
1
0 = 1
1 = 2
535
1
0 = Disable
1 = Enable
536
1
0 = Low
1 = High
540
3
Length: 1

Advertisement

Table of Contents
loading

Table of Contents