HOST MODE PROGRAMMING
PARAMETER
Min Code Position
Filter
Max Code Position
Filter
Check Digit
Check Digit Type
(only for Interleaved
2 of 5)
Check Digit Type
(only for Code 39)
Check Digit
Transmission
Match String Rule
Pattern Match
String
Match Direction
Rule
Code Label Local
No Read String
32
COMPLETE PATH
/Codes
/Code#N
/MinCodePos
/Codes
/Code#N
/MaxCodePos
/Codes
/Code#N
/CheckDigit
/Codes
/Code#N
/CheckDigit25IL
/Codes
/Code#N/
/CheckDigit39
/Codes
/Code#N
/CheckDigitTx
/Codes
/Code#N
/MatchStrRule
/Codes
/Code#N
/PatMatch
/Codes
/Code#N
/MatchDirectionRule
/Codes
/Code#N
/LocNoRead
SHC
PT
VALUE
53 = 549
54 = 559
55 = 569
56 = 579
57 = 589
58 = 599
59 = 609
60 = 619
262
0
Range: 0 to 255
#N
263
0
Range: 0 to 255
#N
5
1
0 = Disable
#N
1 = Enable
526
1
0 = Standard
#N
1 = German
2 = DHL
3 = Daimler-Chrysler
4 = Bosch
527
1
0 = Standard
#N
1 = Mod 7
524
1
0 = Disable
#N
1 = Enable
530
1
0 = Match
#N
1 = Do Not Match
531
3
Length: 0 to 200
#N
529
1
0 = Disable
#N
1 = Forward
2 = Reverse
18
3
Length: 0 to 48
#N