Pepperl+Fuchs VB14N Manual page 51

Host mode programming
Hide thumbs Also See for VB14N:
Table of Contents

Advertisement

HOST MODE PROGRAMMING
PARAMETER
MAIN SERIAL PORT / HEARTBEAT
Timeout (s)
Heartbeat Header
String
Heartbeat Fields
Separator String
Counter Module
(Maximum Counter
Value)
Custom Counter
Module
Counter Starting
Value
Counter Direction
System Diagnostics
Network
Diagnostics
Heartbeat
Terminator String
MAIN SERIAL PORT / LINE PARAMETERS
Main Port
Communication
mode
COMPLETE PATH
/Comms
/SerMain/HeartbeatM
/TimeOutM
/Comms
/SerMain/HeartbeatM
/HeaderM
/Comms
/SerMain/HeartbeatM
/SeparatorM
/Comms
/SerMain/HeartbeatM
/CounterModM
/Comms
/SerMain/HeartbeatM
/CustomCounterModM
/Comms
/SerMain//HeartbeatM
/CounterStartM
/Comms
/SerMain/HeartbeatM
/CounterDirectionM
/Comms
/SerMain//HeartbeatM
/SysDiagM
/Comms
/SerMain/HeartbeatM
/DevDiagM
/Comms
/SerMain/HeartbeatM
/TerminatorM
/Comms
/SerMain/Line
/Mode
SHC PT
VALUE
5079 0
Range: 1 to 3600
5075 3
Length: 0 to 128
5076 3
Length: 0 to 128
5071 1
0 = Disable
1 = 10
2 = 100
3 = 1000
4 = 10000
5 = Custom
5073 0
Length: 2 to 10000
5072 0
Length: 0 to 9999
5070 1
0 = Up
1 = Down
5077 1
0 = Disable
1 = Enable
5074 1
0 = Disable
1 = Enable
5078
Length: 0 to 128
33
1
0 = Standard
1 = MUX 32 Slave
2 = Siemens 3964
3 = Siemens RK512
49

Advertisement

Table of Contents
loading

Table of Contents