Pepperl+Fuchs VB14N Manual page 14

Host mode programming
Hide thumbs Also See for VB14N:
Table of Contents

Advertisement

HOST MODE PROGRAMMING
Using Short Parameter Description (Shortcut)
The 'Set Shortcut' programming string (based on the short parameter description)
must have the following format:
Where:
SS:
SHORTCUT:
VALUE:
After entering this command, the device responds with the proper reply message and
then waits for one or more programming strings.
If the programming is correct, the device updates the configuration and confirms with
the following message:
Where:
VALUE:
If programming contents are wrong (i.e. a typing error in the file) or due to a
transmission error, the device replies with the following message and programming
data will not be updated in this case:
Where:
ERRCODE:
The complete Error Codes table is provided in the Paragraph 5.3.
12
SS<space>SHORTCUT:VALUE<CR><LF>
'Set Shortcut' command
Short Parameter Description (SHC)
Parameter Value
Y<space>VALUE<CR><LF>
Parameter Value
N<space>ERRCODE<CR><LF>
Error Code (signed DEC value)

Advertisement

Table of Contents
loading

Table of Contents