Twinsafe; The I/O Construction Kit Is Extended Safely; Safety Concept - Beckhoff EL6900 Operating Instructions Manual

Twinsafe logic terminal
Hide thumbs Also See for EL6900:
Table of Contents

Advertisement

System description
2.2

TwinSAFE

2.2.1

The I/O construction kit is extended safely

With the TwinSAFE Terminals, Beckhoff offers the option of simply expanding the proven Bus Terminal
system, and to transfer the complete cabling for the safety circuit into the already existing fieldbus cable.
Safe signals can be mixed with standard signals without restriction. This saves design effort, installation and
material. Maintenance is simplified significantly through faster diagnosis and simple replacement of only a
few components.
The new ELx9xx series Bus Terminals only include three basic functionalities: digital inputs EL19xx, digital
outputs EL29xx and a logic unit EL6900. For a large number of applications, all sensors and actuators can
be wired on these Bus Terminals. The required logical link of the inputs and the outputs is handled by the
EL6900. For small to medium-sized configurations, the tasks of a fail-safe PLC can thus be handled within
the Bus Terminal system.
2.2.2

Safety concept

TwinSAFE: Safety and I/O technology in one system
• Extension of the familiar Beckhoff I/O system with TwinSAFE terminals
• Freely selectable mix of safe and standard signals
• Logical link of the I/Os in the EL6900 TwinSAFE logic terminal
• Safety-relevant networking of machines via bus systems
TwinSAFE protocol (FSoE)
• Transfer of safety-relevant data via any media ("genuine black channel")
• TwinSAFE communication via fieldbus systems such as EtherCAT, Lightbus, PROFIBUS or Ethernet
• IEC 61508:2010 SIL 3 compliant
Configuring instead of wiring: the TwinSAFE configurator
• Configuration of the TwinSAFE system via the TwinCAT System Manager
• System Manager for editing and displaying all bus parameters
• Certified function blocks such as emergency stop, operation mode, etc.
• Simple handling
• Typical function blocks for machine safety
• any bus connection with the EL6900 TwinSAFE logic terminal
TwinSAFE logic Bus Terminal EL6900
• Link unit between TwinSAFE input and output terminals
• Configuration of a simple, flexible, cost-effective, decentralized safety controller
• No safety requirements for higher-level control system
• TwinSAFE enables networks with up to 65535 TwinSAFE devices
• TwinSAFE logic terminal can establish up to 128 connections (TwinSAFE connections).
• Several TwinSAFE logic terminals are cascadable in a network
• Safety functions such as emergency stop, protective door, etc. are already included
• Suitable for applications up to SIL 3 according to IEC 61508:2010 and
DIN EN ISO 13849-1:2006 (Cat 4, PL e).
TwinSAFE digital input (EL1904) and output terminal (EL2904)
• All current safety sensors can be connected
12
Version: 2.2.0
EL6900

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents