5
Commissioning and in operation
5.7

Fieldbus configuration (via DIP switches)

5.7.1

Overview of DIP switches [S1.1...12]

Fig. 5.13 Overview of DIP switches [S1.1...12]
5.7.2

Configure fieldbus address/MAC-ID

The address/MAC-ID can be configured via the DIP switches [S1.1...7].
Fieldbus
CANopen
CAN address (1...127)
DriveBus
CAN address (2...13)
PROFIBUS DP
1)
Bus address (3...126)
DeviceNet
MAC-ID (0...63)
RS485
Address (0...127)
Example: address "57" =
(switch position)
1) The addresses "0...2" in Profibus DP are assigned to defined interfaces (e.g.: higher-order controller, etc.).
Tab. 5.5 Configure address of the fieldbus/MAC-ID
60
DIP switch
S1.7
S1.6
S1.5
Bit 6
Bit 5
Bit 4
6
5
4
2
= 64 2
= 32 2
X
X
X
X
X
X
X
X
X
X
X
+ 0
+ 32
+ 16
(OFF)
(ON)
(ON)
Festo – GDCP-CMMS-AS-G2-FW-EN – 1310NH – English