Clearances

When installing a shelf over the top of the fireplaces, the following
guidelines must be adhered to:
DRSQ38*I
21"
17"
1.5"
DRSQ38*I-2
21"
17"
1.5"
Figure 4. Combustible Wall Clearances
NOTES:
Clearance from top of fireplace to a ceiling within the fireplace
enclosure.
WARNING
When this appliance is installed directly on ANY combustible other
than wood flooring (carpet, vinyl, etc.). It must be installed on an
equivalent wood or metal panel. This material must extend the full
width and depth of the appliance.
NOTICE
Clearances must be in accordance with local installation codes and
the requirements of the gas supplier
XG0230 - 052020
1'' all around
1"
0"
6"
2" on the
horizontal
1'' all around
0"
0"
6"
2" on the
horizontal

Section 3: Venting

Montigo offers a variety of direct venting and termination options. The
direct vent termination location MUST be selected such that it is the
highest point in the venting assembly. It should also be selected such
that it provides the shortest vent run possible. Should it be impossible
to ensure that the termination is the highest point or to meet the
venting guidelines laid out below please contact your Montigo dealer
to discuss power venting options.
Notes For Planning Venting:
• Venting originates from the top or rear of the unit
• Venting can terminate through the roof or through an exterior wall.
• Refer to Appendix A - Termination Locations to ensure the planned
termination location is acceptable.
• Once the termination location has been established, refer to the
appropriate section below for installation details
• All fireplaces shipped from the factory are top vent.
• Silicone application is NOT required when joining Montigo vent
pipes and components.
NOTICE
Under no circumstances can Montigo flex venting be cut to
accommodate an installation. Use an alternative length to complete
your vent run. (Excluding flex included in the PVK05, MVK05)
PVK05 (5/8), PVK05F (5/8)
PVK05 Flex Vent Kit is a standalone 5 ft. vent kit that cannot
be combined with Montigo Flex or Montigo Rigid pipe to
extend beyond the 5ft of flex included in this kit. The Flex in
this kit can be cut down if shortening is required. Any other
venting configuration beyond the 5ft included in the kit will
require going to either Montigo Rigid pipe or Montigo Flex pipe
referenced in the manual pages Venting section.
PVK05 Includes RHS101 heat shield, 5' flex pipe (with spacers),
and PTO4 termination
PVK05F (WITH TERM. FRAME) Includes RHS101 heat shield, 5'
flex pipe (with spacers), and PTO4F termination
Figure 4.a PVK05F Flex Vent Kit shown
Installation
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Drsq38niDrsq38ni-2Drsq38liDrsq38li-2Drsqc38niDrsqc38ni-2 ... Show all