Montigo DL6315 Installation & Maintenance Manual

Distinction indoor gas fireplace, 40,000/50,000 btu/hr natural gas or propane gas
Table of Contents

Advertisement

WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury,
death, or property damage.
— Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neighbour's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a qualified
installer, service agency or the gas fitter.
Installation & Maintenance Manual
Distinction
DL6315, DL6315ST,
40,000 BTU/hr Natural Gas or Propane Gas
D6315, D6315ST
50,000 BTU/hr Natural Gas or Propane Gas
• The installation of this fireplace must be done by a
®
• Check local codes and read all instructions prior to
C
US
Installer: Leave this manual with the appliance.
Consumer: Retain this manual for future reference.
INDOOR GAS FIREPLACE
qualified and certified gas appliance installer.
installation.
NOTICE
Installation and service must be performed by a qualified installer,
service agency or the gas fitter.
Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing
XG0221

Advertisement

Table of Contents
loading

Summary of Contents for Montigo DL6315

  • Page 1 Installation & Maintenance Manual Distinction INDOOR GAS FIREPLACE DL6315, DL6315ST, 40,000 BTU/hr Natural Gas or Propane Gas D6315, D6315ST 50,000 BTU/hr Natural Gas or Propane Gas • The installation of this fireplace must be done by a qualified and certified gas appliance installer. ® • Check local codes and read all instructions prior to installation. NOTICE WARNING: FIRE OR EXPLOSION HAZARD Installer: Leave this manual with the appliance.
  • Page 2: Safety Alert Key

    Introduction Congratulations on your purchase of a Montigo Fireplace. With over 30 years of experience, Montigo is committed to providing you with a gas fireplace that is not only a beautiful addition to your space, but that is also designed and manufactured to the highest safety, reliability and engineering standards.
  • Page 3: Table Of Contents

    Section 9: Installing the Fireglass ................36 Installing the See Through Fireplace ............... 12 Firestone & Fireglass Quantity ................. 36 Assemble Non Combustible Framing D/DL6315/ST (Detail) ......13 Optional speckled stones ................36 Framing Box Assembly Single Sided ............... 14 Optional Log Set ....................
  • Page 4: Section A: Before You Begin

    NOTICE • Should it be impossible to meet the venting requirements laid out in Section 3: Venting, please contact your Montigo dealer regarding the use of a Montigo Power Vent. Do not use this appliance if any part has been under water.
  • Page 5: Standard Installation Checklist

    Date Installed: Install Address: Location of Fireplace: Installer: Dealer Phone: Model (circle one): D6315 DL6315 DL6315ST D6315ST Serial #: IF NO, WHY NOT? Appliance Install: Section 2 Framing complies with install manual. Standoffs have been installed. Proper clearances have been maintained.
  • Page 6: Rating Plate Sample

    General Rating Plate Sample Figure 1.b Rating Plate for DL6315 Figure 1 Rating Plate for D6315 XG0221...
  • Page 7: Section 1: Product Dimensions

    TOLERANCES: REVISIONS FRACTIONAL 1/32" 1/2/2017 Drawn by TWO PLACE DECIMAL .015" DWG. NO. DL63-Full Assembly 16 Figure 2. DL6315, D6315 Fireplace dimensions (Tolerance ± ⅛"). THREE PLACE DECIMAL .005" Revision / Date REV. DESCRIPTION DATE CHANGED BY ANGULAR Revision MATERIAL...
  • Page 8 General SEE-THRU D6315ST, DL6315ST Inches Top View 7/16 1851 16 " 1666 9/16 16 " 16 " 1628 1851 8 " 1666 7/16 16 " 16 " 5/16 16 " 16 " 6" 7/16 16 " 8 " 11/16 8 " 8 "...
  • Page 9 Note: Images are shown without screens for clarity purposes. However, your fireplace should not be operated without proper installation of screens. D6315 38⅞'' DL6315 DL6315ST 38⅞'' D6315ST NOTICE Figure 3. Combustible Wall Clearances † Note: Clearance from top of fireplace to a combustible ceiling within the fireplace enclosure.
  • Page 10: Section 2: Framing

    Figure 4. Raised Installation Framing - Single Sided Figure 4.b Raised Installation Framing - See Through *24'' platform height requires *24'' platform height requires D6315, DL6315 D6315ST, DL6315ST a minimum of 8' ceiling height. a minimum of 8' ceiling height.
  • Page 11: Framing The Single Sided Fireplace (Floor Installation)

    Installation Framing the Single Sided Fireplace (Floor Installation) D6315 79 ½'' 18'' 50 ⅜'' WOOD FRAME 72'' 1279 8 " 18'' MIN. MIN. 18" 16 " 2019 50 ⅜'' 2 " MIN. 18'' 1829 72" 79½'' 4 " 72'' MIN. MIN.
  • Page 12: Installing The Single Sided Fireplace

    Installation Installing the Single Sided Fireplace Place the Fireplace on the platform and install the Vent pipe. Next, connect the Gas line, and provide a gas service shut-off valve; according to local gas codes. Before fastening in place line up the front face of the fireplace. Then secure in place with 1/4" lag bolts to the platform. 3.3'' CLEARANCE INTAKE/EXHAUST VENTING GAS AND ELECTRICAL...
  • Page 13: Assemble Non Combustible Framing D/Dl6315/St (Detail)

    Installation ITEM PART NUMBER DESCRIPTION QTY. Non-Combustible stud, DL63190-20 Horizontal DL63192-20 Non-Combustible stud, Vertical Non-Combustible Stud DL63189-20 Assemble Non Combustible Framing D/DL6315/ST (Detail) Connector UMBER DESCRIPTION QTY. Non-Combustible stud, Horizontal Non-Combustible stud, Vertical Non-Combustible Stud Connector 16 " 16 " 16 " 8 " 8 "...
  • Page 14: Framing Box Assembly Single Sided

    Installation Framing Box Assembly Single Sided Framing Box Assembly See-Through Figure 8. Framing Box Assembly Single Sided Figure 8.b Framing Box Assembly See-Through D6315 D6315ST 21 ½'' 18 7/16'' 89 ½'' 89 ½'' 79 ½'' 79 ½'' 50 ⅜'' 50 ⅜'' 72'' 72'' 18'' 18 7/16'' 50 ⅜'' 50 ⅜'' 18'' 18 7/16''...
  • Page 15 Installation Framing with Cool Wall Advantage Below are basic instructions on the framing of the Cool Wall advantage kit. More detailed instructions including the installation diagrams are included with the kit. 2015.73 2015.73 79.4 79.4 1677.92mm 66.060in 1653mm 65in 2x4 On Edge 2x4 On Edge 236mm Opening 9.28in...
  • Page 16: Section 3: Venting

    The distinction is supplied with 3 different sized restrictor plates to meet the venting guidelines laid out below please contact your Montigo improve flame efficiency. The size of restrictor used largely depends dealer to discuss power venting options.
  • Page 17: Section 3-3-1: Venting Layouts

    Installation Section 3-3-1: Venting Layouts Vertical Termination Vertical Termination - 2 Elbows *Restrictor may be required *Minimum 24'' from top of unit before attaching an elbow D6315, D6315ST, DL6315, DL6315ST D6315, DL6315 D6315ST, DL6315ST Vertical Horizontal Vertical Horizontal Vertical Minimum Vertical Maximum Minimum Maximum...
  • Page 18: Vertical Termination - 3 Elbows

    Installation Vertical Termination - 3 Elbows Horizontal Termination - 1 Elbow *Minimum 24'' from top of unit before attaching an elbow *Minimum 24'' from top of unit before attaching an elbow D6315, DL6315 D6315ST, DL6315ST D6315, DL6315 D6315ST, DL6315ST Vertical Horizontal Vertical Horizontal Vertical Horizontal Vertical Horizontal Minimum...
  • Page 19: Horizontal Termination - 2 Elbows

    Installation Horizontal Termination - 2 Elbo Horizontal Termination - 2 Elbows *Minimum 24'' from top of unit before attaching an elbow D6315, DL6315 Vertical Horizontal Minimum Maximum H1+H2 2 FT 1 FT 3 FT 4 FT 4 FT 7.5 FT 5 FT 11 FT...
  • Page 20: Horizontal Termination - 3 Elbows

    Installation Horizontal Termination - 3 Elbows Horizontal Termination - 3 Elb *Minimum 24'' from top of unit before attaching an elbow D6315, DL6315 Vertical Horizontal Minimum Maximum V1+V2 H1+H2 2 FT 1 FT 3 FT 4 FT 4 FT 7.5 FT 5 FT 11 FT...
  • Page 21: Section 3-2: Installing A Roof Mounted Direct Vent Termination (Pvtk1Ss)

    Installation Section 3-2: Installing a Roof Mounted Direct Vent Termination (PVTK1SS) This section applies to installations where the direct vent termination will be roof mounted. Section 3-2-1: Venting Layout PVTK1 Termination Selection of components and details of venting lay out should adhere 2' min Storm collar to the following guidelines:...
  • Page 22: Section 3-3: Installing A Wall Mounted Direct Vent Termination

    Installation Section 3-3: Installing a Wall Mounted Direct Vent Termination Installation of termination from inside structure This section applies to installations where the direct vent termination will be wall mounted. A Termination with a MOSR Frame is installed from the inside of the structure.
  • Page 23: Section 3-3-2: Venting Components

    E - Rigid Pipe Extension PXT - 5 (5" f/f Section) • Montigo recommends the use of a flex section for the final pipe PXT - 12 (12" f/f Section) connected directly to the fireplace offering greater flexibility of PXT - 20 (20"...
  • Page 24: Section 3-3-2.2: Simpson Duravent Venting Components

    Installation Section 3-3-2.2: Simpson Duravent Venting Components The following Simpson Duravent venting components are approved for use with Montigo products. Please contact your local Montigo dealer for further information. Component Simpson Duravent Montigo Part Number Part Number Termination PTO4 (3" Length) 58DVA-HC (Horizontal 5/8 vent) PTO4F (3"...
  • Page 25: Section 3-3-2.3: Icc Venting Components

    Components* The following ICC venting components are approved for use with The following Metalfab venting components are approved for use Montigo products. Please contact your local Montigo dealer for with Montigo products. Please contact your local Montigo dealer further information.
  • Page 26: Section 3-5: Heat Shields

    Installation Section 3-5: Heat Shields Installing a Wall Mounted RHS102 Heat shield Drywall / sheetrock RHS101 Heat Shield Outer Section The RHS102 Heat shield must be used if vent pipe passes through a wall or ceiling within 6' of the unit. RHS101 Heat Shield, inner Section Termination To install the RHS102, Slide the Inner Section over the vent pipe that...
  • Page 27 Installation Burner tray Removal Power and gas to the unit MUST be disconnected before installing 5. Carefully slide out burner strip from the firebox. For instructions on how to remove the door please see the door install/removal section. 1. Remove the pilot cover from the burner tray. Figure 12.
  • Page 28: Propane Conversion

    Installation Propane Conversion Tools required To convert the Distinction 2. Loosen the 4 screws securing the burner strip to the stands. from Natural Gas to Propane, install the GCA008 conversion 1). Torx T20 Screw Driver Bit kit for DL units, and the 2).
  • Page 29 Installation 6. Remove pilot hood, then use allen key to remove pilot orifice. 9. The manifold and inlet pressure can be verified by using a manometer and a 1/8” rubber hose attached to the valve ports shown here (top is manifold, bottom is inlet) Figure 13.e Removing the pilot hood, orifice 7.
  • Page 30: Section 4: Wiring

    Installation Section 4: Wiring D6315 (ST) (N/L) I-2 Wiring Diagram BATTERY PACK 1.5V AA type 1.5V AA type SPARK GREEN 1.5V AA type MAIN WHITE Power 1.5V AA type BLACK BLACK 120VAC 60 Hz SENSOR 6 Amps MAIN ON/OFF SWITCH VARIABLE SPEED Optional CPI/IPI Jumper OPTIONAL CPI/IPI SWITCH...
  • Page 31: Dl6315 (St) (N/L) I Wiring Diagram

    Figure 15. DL6315 (ST) (N/L) I Wiring Diagram Installation of the wall switch Montigo supplies 15' of low voltage wire to be plugged into the control board. Connect to a standard single pole ON/OFF switch to the location of your choice. You may extend these wires up to 100' in length with a wire of equal quality.
  • Page 32: Why Use Cpi Mode

    Installation CPI [Continuous Pilot Ignition] / IPI [Intermittent Pilot Ignition] Jumper Cable Installation “Why use CPI mode”? Installing the CPI Jumper Cable There are several reasons why you may choose to use CPI mode. When 1). Open the control box drawer. a flue is cold it can be difficult to light the appliance. It can take a bit of time (particularly on tall vents) to initialize vent action.
  • Page 33: Section 5: Installing The Gas Line

    Installation Section 5: Installing the gas line Fuel Type Verify that your fireplace is compatible with your available gas type. Natural Gas or Propane shown by "N" or "L" in your model number on rating plate. See page 26 for instructions on converting to propane. After gas line is connected, each appliance connection, valve and valve train MUST be checked while under normal operating pressure Gas Pressure...
  • Page 34: Mantels & Surrounds

    Installation Mantels & Surrounds Mantels & Surrounds with Cool Wall Kit NOTE: National Canadian Gas Association mantel test requirements are for fire hazard prevention to combustible materials. New technology, to meet consumer and government demands for the wise use of energy, has prompted us to manufacture many models of fireplaces which are hot, fuel and energy efficient.
  • Page 35: Section 8: Removing & Installing The Screen

    Installation Section 8: Removing & Installing the Screen Reinstalling the Screen Removing the Screen Follow the steps below to remove, or install the fireplace screen and Follow the two previous steps to re-install the Distinction fireplace door. Before beginning any screen or glass removal, make sure that the window.
  • Page 36: Removing & Installing The Door

    Installation Removing & Installing the door Removing the door: STEP 2: The Distinction doors are removed in a few simple steps. Follow these The 4 door latches are steps below to unlatch the door buckles and, remove the door. Replace holding the door in place in reverse order. with spring pressure.
  • Page 37: Section 9: Installing The Fireglass

    See the and glass door is removed, place the firestones evenly on the media Montigo web site for photographs and ideas. tray as shown in Figures 22 and 22a.
  • Page 38: Optional Log Set

    Installation Optional Log Set The Fireplace has the option of installing a drift wood log set. Once the base media of fireglass, firestones, or speckled stones has been placed the log set can be installed. Ensure logs are securely placed and will not tip or fall. NO LOGS SHOULD LAY ACROSS OR OVER TOP OF THE BURNER FLAME.
  • Page 39 Installation STEP 7: Place log B with one end resting on top of log C. STEP 10: Place log number 3 diagonally in the rear right corner of the firebox. Figure 23.i Figure 23.l STEP 8: Place log 5 at the front of the burner tray. STEP 11: Log 2 rests with one end on top of log 3.
  • Page 40: D6315 (St) (N/L) I-2 Wiring Diagram

    Installation Control Board upgrade/replace 4. New Board. Adding options to DL units requires control board upgrades for the following Pilot When upgrading the options Distinction control board, Fan Kit DFK-3 the board will be shipped On/Off with the board installed in LED Kit MCLEDDL63 Switch the drawer and with the Remote Control...
  • Page 41 Installation 5. Feed On/Off switch 6. Feed Fan, LED, PPO, and 9. Place on LED wire on rightside firebox floor with adhesive wire through drawer frame pilot wires through drawer pad. For LED Install instructions see Optional LED kit Install/ frame. Replace instructions Figure 24.e On/Off switch through drawer Figure 24.f Fan, LED, PPO, and pilot wires Figure 24.i LED wire...
  • Page 42: Led Strip Instructions

    Installation LED Strip Installation (Optional Accessory) LED Strip Instructions 4. Place Glass plate where metal plate sat before, secure using Power to the unit MUST be disconnected before installing existing metal brackets. Screw in halfway on one side first, then fully on the other side, then fully tighten first side. For instructions on how to remove the door please see the door install/removal section.
  • Page 43: Before You Begin

    Installation Optional Glass Reflective panel Installation Before you begin: Installation: Always ensure the kit part number is correct for the fireplace model Step 1: Remove the existing screws in the back and side walls of the and all kit contents are included. The model number may be found on the rating plate under the valve blind of the fireplace.
  • Page 44 Installation Step 4: Repeat step 3 for middle and left panels. Push panels together to prevent gaps. Figure 26.d Secure panel Step 5: Once the back panels are secure, the 2 side panels can be installed. Figure 26.e Secure panel XG0221...
  • Page 45 Installation should be carried out in a clean environment. WARNING! This modulating conversion kit must ONLY be applied as part of a conversion kit supplied by montigo for the specific appliance, and type of fuel, being converted. WARNING! Correct operation of the system cannot be guaranteed if the conversion kit or valve has been dropped or has sustained a strong impact.
  • Page 46: Before You Begin

    Installation Optional Fan kit Install/Replace CAUTION Ensure that all power to the appliance is off at the electrical breaker or fuse before beginning installation. Ensure gas is turned off at the shutoff valve before beginning installation. 3. Repeat for two remaining fans, making sure connectors are on the right side.
  • Page 47 Operation Main ON/OFF Switch Main Harness Sensor Igniter Stepper Motor Manifold Pressure Test Connection LED1 LED2 Output Regulator Control (Optional) 3.15A Fuse Power Inlet Pressure SW1 = Programing Button Test Connection Pilot Adjustment Screw LED1 = Red Diagnostic Light LED2 = Amber Programing Remote Control Light XG0221...
  • Page 48: Section 7: Finishing The Fireplace

    CHANGED BY THREE PLACE DECIMAL .005" Revision / Date ANGULAR Revision MATERIAL ALL BENDS ARE ASSUMED D6315, DL6315 TO BE 90 UNLESS NOTED Finish SHEET 2 OF 2 OTHERWISE. SCALE 1:32 WEIGHT: THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUCTS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CANADIAN HEATING PRODUCTS IS PROHIBITED.
  • Page 49: Optional Remote Operation

    Operation Optional Remote Operation The Proflame 2 System consists of the following elements: 1. Pilot Assembly Blue Back lit LCD display 2. Proflame Gas Valve. 3. Proflame 2 Control Module On/Off Key 4. Wiring Harness Thermostat Key 5. Variable Speed fans Up/Down Arrow Key 6.
  • Page 50 Operation Initializing the System for the first time Temperature Indication Display 1. Set master override switch to off position. With the system in the "Off" position, press the Thermostat Key and the Mode Key at the same time. Look at the LCD screen on 2. Install four (4) AA batteries into the battery holder. the Remote Control to verify that a C or F is visible to the right of 3.
  • Page 51 Operation Remote-Flame Control Room Thermostat (Remote Control Operation) When you turn on the fireplace it starts on high. The proflame 2 has six (6) flame levels. Each time you press the Down Arrow Key The Remote Control can operate as a room thermostat. The once the flame height will reduce by one step.
  • Page 52 Operation Disabling Thermostat Fan Speed Control The fireplace is equipped with optional hot air circulating fans. Some jurisdictions and bedroom installations require the The speed of the fans can be controlled by the Proflame system. thermostat to be disabled. The fan speed can be adjusted through six (6) speeds. To activate this function use the Mode Key, see Figure 26, to index to the fan 1.
  • Page 53: Led Remote Control Operation

    Operation LED Remote Control Operation Use AUX function to turn power on to LED Speed Brightness Mode State State Static white color Adjustable Unadjustable White color gradual changes Adjustable Adjustable All colors gradual change Adjustable Adjustable Red/green/ blue three colors Adjustable Adjustable gradual change...
  • Page 54: Section 10: Cleaning And Maintenance

    Operation Section 10: Cleaning and Maintenance General Cleaning • Have the fireplace and installation inspected yearly. The When the fireplace is first activated, there may be some smoking inspection must include, but is not limited to, the following: and a visible film may be left on the glass. This is a normal condition, and is the result of burning of protective coatings on new metal.
  • Page 55: Appendix A: Venting Terminations

    Appendix Appendix A: Venting Terminations Covered Covered Alcove Detail Alcove Detail Vinyl Siding 2’ 2’ 2’ 2’ 17.5’’ 29.5’’ 11.5’’ 17’’ Must use Vinyl Siding Termination Shield Location Canada* USA** clearance to the termination frame above grade, veranda, porch, deck, or balcony 12 inches 12 inches clearance to top of doors or operable windows...
  • Page 56: Appendix B: Warranty

    Gas Appliance manufactured by The Companies. you. The duration of any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing This Warranty only covers Montigo Gas Appliances installed in warranty. Some states do not allow limitation on how long an the United States or Canada.
  • Page 57: Appendix C: Amendment

    Appendix Appendix C: Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.2 by adding a second exception as 4. INSPECTION. The state or local gas inspector of the side wall follows: horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes...
  • Page 58 Installation & Maintenance Manual D6315 DL6315 Vented gas fireplace heater XG0221...

This manual is also suitable for:

Dl6315stD6315D6315stDl6315ni

Table of Contents