Clearances

When installing a shelf over the top of the fireplaces, the following
guidelines must be adhered to:
DRL3613*I
21"
2"
DRL4813*I
21"
2"
DRL6013*I
36"
2"
1.75"
Figure 4. Combustible Wall Clearances
NOTES:
Clearance from top of fireplace to a ceiling within the fireplace
enclosure.

Recommended flooring considerations

Flooring such as Luxury Vinyl Plank (LVP) and other vinyl flooring can
be sensitive to radiant heat and changes in temperature. If using vinyl
flooring we recommend you install the fireplace in one of the ways
shown below.
Floor mounted fireplace
24" Min.
hearth
Hearth
The minimum width of the
hearth is equal to the width of
the fireplace.
XG0226 - 042220
1'' all around
1"
0"
6"
2" on the
horizontal
1'' all around
1"
0"
6"
2" on the
horizontal
1'' all around
0"
6"
2" on the
horizontal
Raised fireplace
16" Min.
rise
Flush
Vinyl
Flooring
Raise the fireplace 16" above the
floor to allow for vinyl flooring
to be installed flush to the wall.
(Measured from floor to the
bottom of the door opening)
Clearance to Sprinkler
• Maintain 48" of clearance to openings from which heat is
discharged such as chase venting and Cool Wall Advantage.
• Please follow local building codes to determine what sprinkler
head sensor setting is relevant for your installation.
48"