Elevated Surface Temperatures; Standard Installation; Venting Ports Open W/ Vented Chase; Heat Distribution Kit Installed - Montigo DelRay Square Series Installation & Maintenance Manual

Indoor direct vent gas fireplace
Table of Contents

Advertisement

Elevated surface temperatures
The below are surface temperatures of the area above the fireplace
opening after a 3 hour burn period. Use this guide in good faith to
decide on an appropriate facing material and mantle. A cool wall kit
can aid in lowering surface temperatures as shown.
Tests are based off a 24,000 BTU NG unit.

Standard installation

16" above opening = 150°F
12" above opening = 160°F
8" above opening = 180°F
4" above opening = 200°F
IMPORTANT
Every install requires the
installation of the included
cement board.
Temperatures are based off of
the minimum enclosure size.
Venting ports open w/ vented chase
16" above opening = 100°F
12" above opening = 110°F
8" above opening = 130°F
4" above opening = 140°F
IMPORTANT
Leaving the venting ports open
requires a minimum chase
height of 8' and a chase opening
of at least 100² inches
Combustible surround flush
to opening (requires standard
cement board)
XG0230 - 052020
Heat distribution kit installed
VENTED CHASE
Minimum 100²
inches opening
and 8' chase
IMPORTANT
Heat distribution kits can be
either the form of a sidewall
kit or a TV kit. Both require
HDKPDFK-1 5" flex kit (12'
length)
Combustible surround flush
to opening (requires standard
Installation
16" above opening = 100°F
12" above opening = 110°F
8" above opening = 130°F
4" above opening = 140°F
cement board)
TV KIT
TV recess requires
use of a heat
distribution kit