Side vent - Shelf over fireplace framing
COMBUSTIBLE SHELF
C
SUPPLIED SHEILD
Figure 3.c Combustible Framing for shelves over the fireplace, Side vent.
L38ST
A
1'' Min.
A
B
12'' Max
B
C
12'' Min.
C
Top vent - Alcove over fireplace
framing
Ceiling Level
Combustible
header
A
Non-
combustible
nailing flange
(supplied)
Both sides
typical
B
Figure 3.b Non Combustible Framing with alcove above fireplace, Right side. Combustible
Framing above fireplace, Left side, see figure 2. (Top Vent).
L38ST
A
84'' Min.
B
39''
C
33 ¼''
XG0223
NG AND
PROPANE OK
A
A
Side vent - straight
out the wall venting
not permitted for
L42 and L52 units
B
L42ST
L52ST
1'' Min.
Side vent not
12'' Max
available on
L52ST units
12'' Min.
Non-combustible
materials. Alcove
over fireplace
1" Min.
Non-Combustible
header
10"
7"
C
Door
Opening
Floor
L42ST
L52ST
A
95''
A
B
40''
B
C
30 ½''
C

Clearances

L38ST, L42ST, L52ST:
1" clearance is maintained on sides and bottom of vent runs and 2"
above horizontal vent runs to any combustible material.
L38DF-ST
L42DF-ST
L52DF-ST
Figure 4. Combustible Wall Clearances
L38-ST NOTES:
Clearance from top of fireplace to a ceiling within the fireplace enclosure.
When installing a shelf over the top of the fireplace, the following guidelines
must be adhered to: For Side Vent applications, the minimum clearance is
10" from the top of the fireplace to the underside of any combustible shelf.
For Top Vent applications, the minimum clearance is 17½" from the top of
the fireplace to the underside of any combustible shelf.
L42-ST NOTES:
Clearance from top of fireplace to a ceiling within the fireplace enclosure.
When installing a shelf over the top of the fireplace, the following guidelines
must be adhered to: For Side Vent applications, the minimum clearance is
12" from the top of the fireplace to the underside of any combustible shelf.
For Top Vent applications, the minimum clearance is 17" for LP and 12" for
NG from the top of the fireplace to the underside of any combustible shelf.
L52-ST NOTES:
Clearance from top of fireplace to a ceiling within the fireplace enclosure.
When installing a shelf over the top of the fireplaces, the minimum clearance
is 30" to the underside of any combustible shelf materials.
84'' Min.
39''
33 ¼''
Installation
17 ½"
10"
1"
0"
12" NG
12"
2"
0"
17" Propane
30"
24"
1"
0"
See Section 6 Finishing
around the fireplace
See Section 6 Finishing
around the fireplace
See Section 6 Finishing
around the fireplace