Technical Parameters - Goodwe NS Series User Manual

Solar inverter
Hide thumbs Also See for NS Series:
Table of Contents

Advertisement

Type of fault
Relay-Check Failure
DCI Injection High
1. Turn off DC switch of the inverter.
Inverter
EEPROM R/W Failure
2. Wait till the inverter's LCD light is off.
Failure
3. Turn on DC switch and make sure it is connected.
SPI Failure
4. If the problem still exists, contact local service office for help.
DC BUS High
GFCI Failure
1. Turn off DC switch, take off DC connector, measure the voltage of PV array.
2. Plug in DC connector, and turn on DC switch.
Others
No display
3. If PV array voltage is lower than 250V , please check configuration of inverter
module.
4. If voltage is higher than 250V , please contact local office.
Note:
When sunlight is insufficient, the PV inverter may continuously start up and shut down automati-
cally due to insufficient power generation from the PV panels, which would not lead to inverter
damage.
27
Troubleshooting

7 Technical Parameters

Technical Data
PV String Input Data
Max. DC Input Power (W)
Max. DC Input Voltage (V)
MPPT Range (V)
PV Input Operating Voltage Range
Start-up Voltage (V)
Nominal DC Input Voltage (V)
Max. Input Current (A)
Max. Short Current (A)
Maximum Inverter Backfeed Current to Array
No. of MPP Trackers
No. of Input Strings per Tracker
AC Output Data
Nominal Output Power (W) [1]
Max. Output Apparent Power (VA)
Nominal Output Voltage (V)
Nominal Output Frequency (Hz)
Max. Output Current (A)
Output Power Factor
Output THDi (@Nominal Output)
Efficiency
Max. Efficiency
Europe Efficiency
Protection
Anti-islanding Protection
Input Reverse Polarity Protection
Insulation Resistor Detection
Residual Current Monitoring Unit
Output Over Current Protection
Output Short Protection
Output Over Voltage Protection
Protective Class
General Data
Operating Temperature Range (℃)
Relative Humidity
Operating Altitude (m)
Cooling
User Interface
Communication
Weight (kg)
Size (Width*Height*Depth mm)
Protection Degree
The Decisive Voltage Class (DVC)
Night Self Consumption (W)
Topology
Certifications & Standards
Grid Regulation
Safety Regulation
EMC
GW1000-NS
GW1500-NS
GW2000-NS
1300
1950
500
500
80~450
80~450
80~500
80~500
80
80
360
360
10
10
12.5
12.5
0
0
1
1
1
1
1000
1500
1000
1500
220/230
220/230
50/60
50/60
5
7.5
~1 (Adjustable from 0.8 leading to 0.8 lagging)
<3%
<3%
96.5%
97.0%
96.0%
96.0%
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Protective Class I
-25~60
0~100%
≤4000
Natural Convection
LCD & LED
RS485 or WiFi
7.5
344*274.5*128
IP65
DVC- C
<1
Transformerless
Visit homepage to achieve information.
2600
500
80~450
80~500
80
360
10
12.5
0
1
1
2000
2000
220/230
50/60
10
<3%
97.0%
96.0%
28