3.2 Package

The unit is thoroughly tested and strictly inspected before delivery. Damage may still occur during
shipping.
1. Check the package for any visible damage upon receiving.
2. Check the inner contents for damage after unpacking.
3. Check the package list below.
Inverter
Wall-Mounted Bracket
or
AC Plug
6-Pin Terminal
Quick Installation
Fixed Screw
Instruction
[1]Positive & Negative Plug:
NS series 1 pair;
DNS series 2 pairs.
05
Expansion Bolts
Positive DC Plug [1]
Negative DC Plug [1]
2-Pin Terminal
Fixed Screw
WiFi Configuration
Instruction

4 Installation

4.1 Mounting Instructions

1. In order to achieve optimal performance, the ambient temperature should be lower than 45℃.
2. For easy maintenance, we suggest to install the inverter at eye level.
3. Inverters should not be installed near flammable and explosive items. Strong electro-magnetic
charges should be kept away from installation site.
4. Product label and warning symbols should be placed at a location that is easy to read by the
users.
5. Make sure to install the inverter at a place where it is protected from direct sunlight, rain and
snow.
Keep away
from sunlight
PE Terminal

4.2 Equipment Installation

4.2.1 Select Installation Location
Please take the following points into consideration when you are selecting a proper location to
install inverter.
• Please choose appropriate mounting methods and installation location in terms of weight and
dimension of inverter.
• The location must be well ventilated and sheltered from direct sunlight.
• Install inverter vertically or with a backward tilt within 15 degrees. No lateral tilt is allowed. The
area of the connectors should point downwards.
To allow for dissipation of heat, and for convenience of dismantling, clearance around the inverter
must follow the below diagram.
The installation position shall not prevent access to the disconnection means.
Keep it clear
Keep dry
Sun
of snow
Max
15°
Rain
Accmulated snow