EXPLANATION OF COMPONENTS
5.
Press the menu switch to display "Aftertreatment Devices
Regeneration" screen.
6.
Select the manual stationary regeneration, check again safety of the surrounding area and make sure the
area is free from irrelevant people or combustible material, then press ENTER switch.
If the machine needs to be moved again to secure safety, move it to a safe place and repeat the procedure
from step 1.
After ENTER switch is pressed in step 6, the screen
shown in the figure may be displayed. This indicates that
the operations in steps 1 to 3 were not performed correctly
or there is trouble other than the deterioration of regenera-
tion performance. Check operation of the engine, make
sure you are not depressing the accelerator pedal and
check the position of the directional lever and parking
brake switch, then repeat the procedure from step 5.
If the manual stationary regeneration still cannot be per-
formed, return to the standard screen, press ENTER
switch to check the contents of other occurring troubles,
and take the necessary remedy.
The explanation of the manual stationary regeneration
is displayed in 3 parts on the monitor panel. When
ENTER switch is pressed, the regeneration can be
started immediately, regardless of which part is dis-
played. When RETURN switch is pressed, the display
returns to the standard screen.
If no monitor switch is operated for 30 seconds, the
explanation display of the manual stationary regenera-
tion is not displayed and the screen returns to the
standard screen. At this time, to display the explana-
tion of the manual stationary regeneration again,
press ENTER switch on the standard screen to dis-
play "Aftertreatment Devices Regeneration" screen.