Komatsu WA200-8 Operation & Maintenance Manual page 180

Wheel loader
Table of Contents

Advertisement

EXPLANATION OF COMPONENTS
Press the menu switch on the standard screen to display "Aftertreatment Devices Regeneration" screen of the
user menu.
Low-level requirement for regeneration
When caution lamp (2) comes on in yellow (action level
(3): "L01"), screen (A) is displayed first.
The action level goes out after 2 seconds and the screen
changes to standard screen (B).
If the machine is completely stopped, the display switches
to "Aftertreatment Devices Regeneration" screen (C) after
3 seconds only the first time. If, however, the manual sta-
tionary regeneration is not performed, the display returns
to standard screen (B) after 30 seconds.
The "Aftertreatment Devices Regeneration" screen (C) is
shown for 30 seconds every 2 hours until regeneration is
performed.
When caution lamp (2) comes on in yellow, after the end of
ongoing work stops the machine in a safe area and acti-
vate manual stationary regeneration.