READ BEFORE BEGINNING INSTALLATION/PROGRAMMING/SET-UP
SAFETY
CAUTION!
Use of controls, adjustments, or performance of procedures other than those specified herein
may result in hazardous radiation exposure.
Do not look into the laser
emitter or the visible red laser
beams.
This sensor is designed to be used as a movement and presence sensor to control the opening and the closing process
of a gate or a barrier. The installer of the system is responsible for installing the sensor and the system in compliance
with applicable national and international standards on safety. The manufacturer of the sensor cannot be held
responsible for incorrect installations or inappropriate adjustments of the sensor.
This device is not intended for use in with any automatically activated doors. US Pat. No. 7,084,388, which is not
owned by BEA, covers automatic doors comprising, among other things, a scanning detector. The LZR-H100 is not
sold with consent, implied or otherwise, for use with automatically activated doors, as set forth in the aforementioned
patent.

INSTALLATION AND MAINTENANCE

Avoid extreme vibrations.
Avoid exposure to
sudden and extreme
temperature changes.
Page 2 of 16
The device emits invisible (IR) and visible laser radiation.
The visible laser beams are inactive during normal operation.
The installer can activate the visible lasers if needed.
Do not stare into visible laser beams.
The warranty is void if
unauthorized repairs are made
or attempted by unauthorized
personnel.
Do not cover the laser
Avoid moving objects
windows.
and light sources in front
of the laser window.
Avoid direct exposure to
high pressure cleaning.
IR laser: wavelength 905nm; output power 0.10mW
(Class 1 according to IEC 60825-1)
Visible laser: wavelength 635nm; output power 0.95mW
(Class 2 according to IEC 60825-1)
Only trained and qualified
personnel are recommended to
install and set up the sensor.
Avoid the presence of
smoke and fog in the
detection field.
Do not use aggressive
products to clean the
laser windows.
After installation, enter
an access code by remote
control.
Avoid condensation on
the laser windows.
Clean the laser window
Keep the sensor
with compressed air. If
permanently powered in
needed, wipe only with
environments where the
a soft, clean and damp
temperature can drop
microfibre cloth.
below 35 °F.
75.5984.03 LZR-H100 20191125