Recommended Mounting - BEA LZR-H100 User Manual

For barriers & gates with max. detection range of 32' x 32'
Hide thumbs Also See for LZR-H100:
Table of Contents

Advertisement

RECOMMENDED MOUNTING

Install the sensor at a mounting height between
14 – 17 inches. If the barrier is only used by truc-
ks, the mouting height may be increased.
Ensure that the detection field is parallel to the
barrier.
When using the safety field, place the sensor
just behind the barrier to ensure that the safety
field protects the area around the barrier.
d (in)
2
4
6
Ensure there are no obstructions in front of the
sensor!
75.5984.03 LZR-H100 20191125
14 – 17 in
L
(in) h
(in)
min
min
9.5
2
14
2.3
19
2.5
If the 0º reference beam is too low or too high,
vehicle contact with the barrier may occur.
Do not position the detection field as shown.
B
A
When using the safety, do not place the sensor
before the barrier (A) or more than 15 inches after
the barrier (B). The area around the barrier is not safe.
Do not cover the front face of the sensor with
glass or plastic.
Page 7 of 16

Advertisement

Table of Contents
loading

Table of Contents