LASER SCANNERS foR INduStRIAL dooRS
I100: max. detection range of 9.9 m x 9.9 m
I110: max. detection range of 5.0 m x 5.0 m
Safety Commissioning Guide

Advertisement

loading

Summary of Contents for BEA LZR-I100

  • Page 1 ® -I100/ -I110 LASER SCANNERS foR INduStRIAL dooRS I100: max. detection range of 9.9 m x 9.9 m I110: max. detection range of 5.0 m x 5.0 m Safety Commissioning Guide...
  • Page 2: Installation And Maintenance

    SAFETY The device contains IR and visible laser diodes. IR laser: wavelength 905nm; max. output pulse power 75W (Class 1 according to IEC 60825-1) Visible laser: wavelength 650nm; max. output CW power 3mW (Class 3R according to IEC 60825-1) The visible laser beams are inactive during normal functioning. The installer can activate the visible lasers if needed.
  • Page 3 WIRING GREEN Use the Power Supply Module POWER SUPPLy (24V DC, 0.75 A) if needed. BROWN WHITE RELAy 1 - OPTIONAL FIELD yELLOW The sensor tests both relays. PINK RELAy 2 - SAFETy FIELD VIOLET CAT2 Door control without test: Pl d TEST connect red and blue wires to...
  • Page 4 MOuNTING SIDE Check and select the corresponding mounting side if necessary. Stay outside of the detection field to avoid disturbances. CAT2 CAT2 Pl d Pl d right left right left centre WITH BACKGROUND WITHOUT BACKGROUND No reference point, no signal. The sensor memorizes the floor as reference point and signals a fault when its orientation is changed.
  • Page 5 SAFETY FIELD CONFIGuRATION (RELAY 2) FIELD DIMENSIONS After the teach-in, the field dimensions can be reduced by remote control. -I110 -I100 ® ® WIDTH 0.5 m 9.9 m no field no field 0.5 m 5.0 m 5.0 m HEIGHT 0.5 m 9.9 m 0.5 m 5.0 m...
  • Page 6: Troubleshooting

    TROuBLESHOOTING There is no power. No blue LED Check cable and connexion. The polarity of the power Check the polarity of the power supply. supply is inverted. All LEDs have been de- Activate the LEDs by remote control. activated by remote control. Only the blue LED The test input is not Check wiring.