Download Print this page

Installation And Maintenance - BEA LZR-I100 User Manual

Laser scanners for industrial doors - i100: max. detection range of 9.9 m x 9.9 m i110: max. detection ran; ge of 5.0 m x 5.0 m
Hide thumbs Also See for LZR-I100:

Advertisement

SAFETY
CAUTION!
Use of controls, adjustments or performance of procedures other than those specified herein
may result in hazardous radiation exposure.
Do not look into the laser
emitter or the visible red
laser beams.
The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the
door system in compliance with applicable national and international regulations and standards on door safety and if
applicable, the machinery directive 2006/42/EC. Other use of the device is outside the permitted purpose and can not be
guaranteed by the manufacturer. The manufacturer cannot be held responsible for incorrect installations or inappropriate
adjustments of the sensor.

INSTALLATION AND MAINTENANCE

Avoid extreme
vibrations.
Avoid exposure to
sudden and extreme
temperature changes.
2
The warranty is void if
unauthorized repairs are
made or attempted by
unauthorized personnel.
Do not cover
the front screens.
Avoid direct exposure
to high pressure
cleaning.
The device contains IR and visible laser diodes.
IR laser: wavelength 905nm; max. output pulse power 75W
(Class 1 according to IEC 60825-1)
Visible laser: wavelength 650nm; max. output CW power 3mW
(Class 3R according to IEC 60825-1)
The visible laser beams are inactive during normal functioning.
The installer can activate the visible lasers if needed.
Only trained and qualified
personnel may install and
adjust the sensor.
Avoid moving objects
and light sources in
the detection field.
Do not use aggressive
products to clean
the front screens.
Test the good functioning
of the installation before
leaving the premises.
Avoid condensation.
Avoid the presence
of smoke and fog in
the detection field.
Wipe the front
Keep the sensor
screens regularly
permanently powered
with a clean and
in environments where
damp cloth.
the temperature can
descend below 0°C.