TECHNICAL SPECIFICATIONS

Technology:
Detection mode:
Max. detection field:
Min. detection field (safety):
Remission factor:
Angular resolution:
Emission characteristics
IR laser:
Red visible laser:
Supply voltage:
Power consumption:
Peak current @ power-on:
Cable length:
Response time:
motion detection:
presence detection:
Output:
Max. switching voltage:
Max. switching current:
Switching time:
Output resistance:
Voltage drop on output:
Leakage current:
Test input:
Max. contact voltage:
Voltage threshold:
LED signal:
Dimensions:
Material:
Color:
Mounting angles on bracket:
Rotation angles on bracket:
Tilt angles on bracket:
Protection degree:
Temperature range:
Humidity:
Vibrations:
Pollution on front screen:
Norm conformity:
BEA, INC. INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS
BEA, Inc., the sensor manufacturer, cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor/device; therefore,
BEA, Inc. does not guarantee any use of the sensor outside of its intended purpose.
BEA, Inc. strongly recommends that installation and service technicians be AAADM-certifi ed for pedestrian doors, IDA-certifi ed for doors/gates, and
factory-trained for the type of door/gate system.
Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor
system installation is compliant with local, national, and international regulations, codes, and standards.
Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer recommendations
and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices. Safety inspections must be performed during each service
call – examples of these safety inspections can be found on an AAADM safety information label (e.g. ANSI/DASMA 102, ANSI/DASMA 107).
Verify that all appropriate industry signage and warning labels are in place.
General Tech Questions: techservices-us@beasensors.com | Tech Docs: www.BEAsensors.com
Page 16 of 16
laser scanner, time-of-flight measurement (4 laser curtains)
motion and presence
32' x 32' (9
m)
3
4
1' 8" (
m)
1
5
> 2%
0.3516°
wavelength 905 nm; output power 0.10mW (CLASS 1)
wavelength 635 nm; output power 0.95mW (CLASS 2)
10 – 35 VDC
< 5 W
1.8 A (max. 80 ms @ 35 V)
33'
typ. 200 ms (adjustable)
typ. 20 ms (max. 80 ms)
2 electronic relays (galvanic-isolated – polarity-free)
35 VDC / 24 VAC
80 mA (resistive)
t
= 5 ms; t
= 5 ms
ON
OFF
typ 30 Ω
< 0.7 V @ 20 mA
< 10 µA
2 optocouplers (galvanic-isolated – polarity-free)
30 VDC (over-voltage protected)
Log. H: > 8 VDC
Log. L: < 3 VDC
1 blue LED: power-on status
1 orange LED: error status
2 bi-colored LEDs: detection/output status (green = no detection, red = detection)
3
5
"× 2
3
"× 5"(W × H × D)
8
4
PC/ASA
Black
-45°, 0°, 45°
-5 – 5° (lockable)
-3 – 3°
NEMA 4 / IP65
powered: -22 – 140 °F (-30 – 60 ºC)
0 – 95% non-condensing
< 2G
max. 30%, homogenous
2006/95/EC: LVD
2002/95/EC: RoHS
Tech Support & Customer Service: 1-800-523-2462
mounting bracket: +
unpowered: 14 – 140 °F (-10 – 60 ºC)
2004/108/EC: EMC
IEC 60825-1:2007
IEC 60529:2001
IEC 60950-1:2005
Specifications are subject to change without prior notice.
All values measured in specific conditions.
1
"
2
IEC 61000-6-2:2005
IEC 61000-6-3:2006
75.5984.03 LZR-H100 20191125