Replacing Colorvision Light Assembly (After Electrical Requirements Are Met) - Pentair COLORVISION Installation And User Manual

Underwater color changing led light for pool and spa
Table of Contents

Advertisement

16
REPLACING THE COLORVISION™ LIGHT ASSEMBLY
(AFTER ELECTRICAL REQUIREMENTS ARE MET)
The following removal and installation instructions describe how to remove and install
the ColorVision Light assembly. Also use these instructions after completing the
following light replacement procedure.
Failure to bring the pool or spa's electrical system up to code requirements
before installing the underwater light will create an electrical hazard which
could result in death or serious injury to pool users, installers, or others due to
electrical shock, and may also cause damage to property.
1.
Switch off electrical switch or circuit breaker at the source.
2.
Remove Junction Box or Transformer cover. Disconnect the light wires and
attach a fish tape to the existing light power cord. This will assist in pulling
the replacement light power cord through the conduit back to the junction
box.
3.
Remove the lens cover ring, lens retaining screws, lens and diffuser. Remove
the GloBrite color light assembly from the pool or spa water: Using the
provided installation tool (P/N 620057), rotate the light assembly counter-
clockwise about a 1/8th turn to release the light from the niche as shown on
page 10).
4.
Slowly pull the light and attached power cord (with attached fish tape) out of
the niche. Pull the light's power cord and fish tape out of the niche and place
the light on the deck.
5.
Attach the new light power cord to the fish tape and carefully feed the fish
tape and cable to the junction box.
6.
At the 12 VAC transformer or junction box, cut off any extra cord. Leave at
least six (6) inches (15.2 cm) of cord in the Junction Box or transformer to
facilitate the light installation, niche inspection. Cut off any extra cord.
7.
Strip back three (3) inches of the outer cord jacket to expose the two
insulated wires (be careful not to damage the insulation on the two (2) inner
wires). Strip back the two conductors. Be careful not to damage the copper
conductor.
8.
Connect both (2) wires to the corresponding circuit wires in the Junction Box
or 12 Volt AC Transformer (black wire to power, white wire to common) and
secure the Junction Box cover in place.