IMPORTANT WARNING AND SAFETY INSTRUCTIONS
NOTICE: The external flexible cable or cord of this luminaire cannot be replaced; if
the cord is damaged, the luminaire shall be destroyed.
Under no circumstances replace lights by splicing wire under water or
behind niche.
ColorVision™ Light is a 12 VAC system. ONLY USE an approved 12
volt AC transformer, sold separately. When using a Junction Box, connect
12 volt AC connections to junction box terminals. Never connect the light directly
to high voltage lines.
INSTALLERS AND INSPECTORS: THE COLORVISION LIGHT AND PLASTIC
NICHE FORM A COMPLETE NON-METALLIC LOW VOLTAGE LIGHTING SYSTEM.
THIS CONFIGURATION DOES NOT REQUIRE BONDING OR GROUNDING WHEN
POWERED BY A LISTED 100 WATT OR 300 WATT 12 VAC TRANSFORMER AND
INSTALLED IN COMPLIANCE WITH THE CURRENT NATIONAL ELECTRIC CODE
(NEC). UNBONDED LIGHTING NEC PROVISIONS.
WHEN THE UL LISTED NON-METALLIC COLORVISION LIGHT LOW VOLTAGE
LIGHTS ARE USED WITH THE LIGHT APPROVED NICHE, THE CURRENT NEC
PROVIDES AN EXCEPTION TO LUMINAIRE BONDING AND GROUNDING IN
ARTICLE 680.6 AND 680.23 POOL WATER BONDING NEC PROVISIONS: FOR POOL
WATER BONDING REQUIRED BY NEC ARTICLE 680.26C, CONCRETE POOLS ARE
CONSIDERED CONDUCTIVE (REFER TO 680.26 (B)(1) DUE TO THE POROSITY
OF CONCRETE AND THE BONDING OF REBAR. NO ADDITIONAL BONDING IS
REQUIRED.
be installed by a licensed or certified electrician or a qualified pool service person, in
accordance with IEC 364-7-702 and all applicable local codes and ordinance. Improper
installation will create an electrical hazard, which could result in death or serious injury
to pool user, installer or other due to electrical shock and may also cause damage to the
property.
THE GLOBRITE LIGHT IS A NON-SERVICEABLE LIGHT. THE
COMPLETE LIGHT ASSEMBLY MUST BE REPLACED.
COLORVISION Light Installation and User's Guide
For countries in compliance with International Electrotechnical
Commission (IEC) regulatory standards: The light fixture must
IMPORTANT NOTICE: