Process Image; Table 14: Process Image - Signal Voltage U - WAGO I/O-SYSTEM 750-491 Manual

1-channel analog input module for resistor bridges
Hide thumbs Also See for I/O-SYSTEM 750-491:
Table of Contents

Advertisement

22

Process Image

Pos: 22 /Alle Serien (Allgemeine Module)/Überschriften für alle Serien/__ noch nicht einsortierte Überschriften müssen noch einsortiert werden __Prozessabbild - Überschrift 1 @ 4\mod_1240983067828_21.docx @ 31942 @ 1 @ 1
4
Process Image
Pos: 23 /Serie 750 (WAGO-I/O-SYSTEM)/Prozessabbild Klemmenbus/Hinweis: Prozessabbildmapping abhängig von FBK/PFC, mit Status-/Controllbyte @ 4\mod_1242621308640_21.docx @ 33290 @ @ 1
Mapping of process data in the process image of fieldbus systems
The representation of the I/O modules' process data in the process image depends
on the fieldbus coupler/controller used. Please take this information as well as the
particular design of the respective control/status bytes from the section "Fieldbus
Specific Design of the Process Data" included in the description concerning the
process image of the fieldbus coupler/controller used.
Pos: 24 /Serie 750 (WAGO-I/O-SYSTEM)/Prozessabbild Klemmenbus/Hinweis: Statusbyte-Auswertung abhängig vom Feldbussystem @ 6\mod_1256127208766_21.docx @ 43344 @ @ 1
Evaluation of Status Byte
Some fieldbus systems can process status information of process value by means
of a status byte.
This status byte can be displayed via the commissioning tool WAGO-I/O-
CHECK.
However, processing via the fieldbus coupler/controller is optional, which means
that accessing or parsing the status information depends on the fieldbus system.
Pos: 25 /Serie 750 (WAGO-I/O-SYSTEM)/Prozessabbild Klemmenbus/Analogeingangsklemmen/Prozessabbild 750-0491 @ 5\mod_1251701676015_21.docx @ 41080 @ @ 1
The bridge voltage between +U
500 nV/digit, i.e., 10 mV corresponds to an output value of 20000 in data bytes
D0 and D1.
The supply voltage of the measuring bridge is output at a resolution of
500 μV/digit, i.e., 10 V corresponds to an output value of 20000 in data bytes D2
and D3.
Table 14: Process Image – Signal Voltage U
Signal voltage
U
±15 mV
< ca. −15.5000
ca. −15.5000
−15.0000
−10.0000
−5.0000
−0.0005
0.0000
0.0005
5.0000
10.0000
15.0000
> ca. 15.5000
Wire break
D
Binary
Output value
'0111.1111.1111.1111'
'0000.0000.0000.0000'
'1000.1010.1101.0000'
'1011.0001.1110.0000'
'1101.1000.1111.0000'
'1111.1111.1111.1111'
'0000.0000.0000.0000'
'0000.0000.0000.0001'
'0010.0111.0001.0000'
'0100.1110.0010.0000'
'0111.0101.0011.0000'
'0111.1111.1111.1111'
'0111.1111.1111.1111'
and −U
is output at a resolution of
D
D
D
Numeric value
Hex.
0x7FFF
0x0000
0x8AD0
0xB1E0
0xD8F0
0xFFFF
0x0000
0x0001
0x2710
0x4E20
0x7530
0x7FFF
0x7FFF
WAGO-I/O-SYSTEM 750
750-491 1AI DMS
Status
LED
Byte
Hex.
Dec.
32767
0x41
0
0x00
−30000
0x00
−20000
0x00
−10000
0x00
−1
0x00
0
0x00
1
0x00
10000
0x00
20000
0x00
30000
0x00
32767
0x41
32767
0x41
Manual
Version 1.2.0
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON

Advertisement

Table of Contents