Soft configuration will only be used by BIOS code to setup a default video
configuration. GLP does not use the Soft Configuration Data (SCD)
directly to control video mode programming. However, the SCD can be
accessed from GLP via the pk_get_attribute and pk_set_attribute calls.
The following soft configuration variables are defined:
General video parameters
Name
w
h
p
f
P
Video timing override
Name
pf
hf
hp
hs
hb
vp
vs
vb
Register Override *
Name
Wxx
Gxx
Dxx
Cxx
Ixx
Oxx
Rxx
* Note: Name denotes an offset (in hex) from the RBASE_n or
RAMDAC base register address.
4-26 Troubleshooting
Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com
Description
width
height
pixel format
vertical sync frequency
pitch
Description
Pixel frequency
Horizontal frequency
Horizontal front porch
Horizontal sync
Horizontal blanking
Vertical front porch
Vertical sync
Vertical blanking
Description
RBASE_W register override
RBASE_G register override
RBASE_D register override
RBASE_C register override
RBASE_I register override
IO register override
RAMDAC register override
Units
pixels (640 default)
pixels (480 default)
8 (default), 16, 555, or 24
Hz (60 default)
pixels (default to width)
Units
MHz
KHz
microseconds
microseconds
microseconds
milliseconds
milliseconds
milliseconds
Values
32-bit (hex)
32-bit (hex)
32-bit (hex)
32-bit (hex)
32-bit (hex)
32-bit (hex)
byte (hex)