Samson 3965 Mounting And Operating Instructions page 11

Solenoid valve island
Table of Contents

Advertisement

Type 3965 Solenoid Valve Island
Type of protection
No explosion protection
II 2 G Ex ia IIC T6 and II 2 D IP 65 T 80 °C
Ex ia IIC T6 and Ex tD A21 IP 65 T 80 °C
II 3 G Ex nA II T6 or II 3 G Ex nL IIC T6 and II 3 D IP 54 T 80 °C
or II 3 D IP 65 T 80 °C
Ex nA II T6 or Ex nL IIC T6 and Ex tD A21 IP 54 T 80 °C or
Ex tD A21 IP 65 T 80 °C
Electrical connection
Single connector, type C, without cable socket according to
DIN EN 175301-803 (IP 20)
Single connector, type C, with cable socket according to
DIN EN 175301-803 (IP 54)
Common cable (0.25 mm² wire cross-section, 1.5 m long) with
M20x1.5 cable gland, polyamide, IP 54
Multi-pole connector with cable socket, 32-pole, made of gray
polyamide, IP 54
Bus connection for PROFIBUS-DP (Ex ia) with connecting cable,
IP 40, for 6 V DC nominal signal
Nominal signal
6 V DC, 5.47 mW power consumption
12 V DC, 13.05 mW power consumption
24 V DC, 26.71 mW power consumption
Electric status indication
Without
8)
Switching function
3/2-way function (with uneven number of switching function including dummy
plate for a reserve switching function)
5/2-way function
2/2-way function (with uneven number of switching function including dummy
plate for a reserve switching function)
Special switching function or combined switching functions
EB 3965 EN
 1)
 2)
 3)
 4)
Order no. 3965- x x x x x x x x x x x x x 0 0
0 0
1 1
1 2
8 1
8 2
 6)
Markings on the device
0 0
0 1
0 2
1 0
3 1 1
1
2
3
0
0
1
2
9
11

Advertisement

Table of Contents
loading

Table of Contents