Outer Dimensions And Panel Cutout Size; Installation - Fuji Electric PXZ Series Operation Manual

Pid autotune controllers featuring fuzzy logic
Hide thumbs Also See for PXZ Series:
Table of Contents

Advertisement

OUTER DIMENSIONS AND PANEL CUTOUT SIZE

PXZ 4
7
48
F
C
H
L
PV
SV
PV/SV
SEL
DATA
ENT
PXZ-4
Gasket
Gasket
48
9.5
Mounting bracket
Panel cutout size: when installing
"n" numbers of units.
PXZ 5,7,9
A
F
C1
C2
H
L
HB
PV
B
SV
SV
SEL
DATA
ENT
PXZ-
Gasket
Unit: mm
Panel thickness: 1 to 8 mm
Model
A
B
C
D
PXZ5
52.5
100.5
90.5
114.5
PXZ7
76.5
76.5
67
91
PXZ9
100.5
100.5
90.5
114.5
Panel cutout size: when installing
"n" numbers of units.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
85.7
71.5
Panel
Unit: mm
Panel thickness: 1 to 8 mm
63 or more
0.5
45 -0
95.8
16.2
C
D
18.7
Panel
E
F
G
H
0.6
0.8
45
92
120Min.
92Min.
-0
-0
0.7
0.7
68
68
96Min.
116Min.
-0
-0
0.8
0.8
92
92
120Min.
140Min.
-0
-0
E
F
G
H

INSTALLATION

NEMA 4X Integrity
The front side of this instrument conforms to NEMA 4X. To ensure the
waterproofness between the instrument and the panel, use the gasket
that is provided with the unit according to the installation procedure
described below.
How to install the unit
For PXZ-5/7/9, install the two metal brackets, one on the top and the
other on the bottom, and tighten the screws to a torque of about 14.7N-
cm (1.5kg-cm). For PXZ4, install the unit in the panel as shown below,
and tighten the screws on the mounting bracket until the unit is secure.
Make sure there is no space between the front side of the unit and the
gasket, and between the gasket and the panel.
Figure 1
Unit
Front
Gasket
Case
Caution: After the mounting bracket is installed, check the gasket for
displacement and detachment as shown in Figure 3.
Gasket
Case
(Bad)
5
Figure 2
Unit
Panel
Panel
Mounting bracket
Gasket
Figure 3
Case
(Good)
Screw

Hide quick links: