9.2

Acceleration/deceleration pattern

The acceleration/deceleration pattern can be set according to the application.
Pr.
Name
29
Acceleration/deceleration pattern
F100
selection
 Linear acceleration/deceleration (Pr.29 = "0" (initial value))
• When the frequency is changed for acceleration, deceleration, etc. during inverter operation, the output frequency is
changed linearly (linear acceleration/deceleration) to reach the set frequency without straining the motor and inverter.
Linear acceleration/deceleration has a uniform frequency/time slope.
Setting value "0"
[Linear acceleration
/ deceleration]
Time
 S-pattern acceleration/deceleration A (Pr.29 = "1")
• Use this when acceleration/deceleration is required for a short time until a high-speed area equal to or higher than the base
frequency, such as for the main shaft of the machine.
• The acceleration/deceleration pattern has the Pr.3 Base frequency (Pr.84 Rated motor frequency under PM motor
control) (fb) as the point of inflection in an S-pattern curve, and the acceleration/deceleration time can be set to be suitable
for the motor torque reduction in the constant-power operation range at the base frequency (fb) or more.
Setting value "1"
[S-pattern acceleration
/deceleration A]
fb
• Acceleration/deceleration time calculation method when the set frequency is equal to or higher than the base frequency
Acceleration time t = (4/9) × (T/fb
Where T is the acceleration/deceleration time (s), f is the set frequency (Hz), and fb is the base frequency (rated motor
frequency)
• Reference (0 Hz to set frequency) of acceleration/deceleration time when Pr.3 = 60 Hz
Acceleration/deceleration time (s)
5
15
NOTE
• For the acceleration/deceleration time setting of the S-pattern acceleration/deceleration A, set the time to Pr.3 (Pr.84 under
PM sensorless vector control) instead of Pr.20 Acceleration/deceleration reference frequency.
Initial
Setting range
value
0
0
1
2
Time
2
2
) × f
+ (5/9) × T
Set frequency (Hz)
60
120
5
12
15
35
Linear acceleration/deceleration
S-pattern acceleration/deceleration A
S-pattern acceleration/deceleration B
200
400
27
102
82
305
9. (F) Settings for Acceleration/Deceleration