• On the I/O terminal monitor, the upper LEDs indicate the input terminal status, and the lower LEDs indicate the output
terminal status.
I-2
I-3
I-5
I-6
I-1
I-4
O-1
O-4
O-2
O-5
O-3
O-6
Symbol
FR-E800
I-1
RL
I-2
RM
I-3
RH
I-4
I-5
I-6
I-7
MRS
I-8
RES
I-9
STF
I-10
STR
I-11
I-12
• The decimal point of the last digit on the LED is lit for the input option terminal monitor.
X1
X2
X4
X5
X0
X3
X10
X13
X11
X14
X12
X15
• The decimal point of the second last digit on the LED is lit for the output option terminal monitor.
Y1
Y2
Y4
Y5
Y0
Y3
RA1
RA2
RA3
 Monitoring and resetting cumulative power (Pr.170, Pr.891)
• When the cumulative power is monitored (Pr.52 = "25"), the output power monitor value is added up and is updated in 100
ms increments.
• The values are stored in EEPROM every 10 minutes. The values are also stored in EEPROM at power OFF or inverter
reset.
• Increments and ranges of monitoring on the operation panel or via communication are as follows.
Operation panel
Range
0 to 99.99 kWh
100.0 to 999.9 kWh
1000 to 9999 kWh
276
12. (M) Item and Output Signal for Monitoring
12.2 Monitor item selection on operation panel or via communication
I-8
I-9
I-11
I-12
I-7
I-10
O-7
O-10
O-8
O-11
O-9
O-12
Input terminal
FR-E800-E
FR-E800-SCE
DI0
DI1
X7
X8
X6
X9
DY
Decimal point LED of the last digit LED is always ON
Y6
Decimal point LED of the second last digit LED is always ON
*1
Increment
Pr.170 = "10"
0.01 kWh
0.1 kWh
0 to 9999 kWh
1 kWh
Segments corresponding
to input terminals
The center LED segments are
always ON.
Segments corresponding
to output terminals
Symbol
FR-E800
O-1
A,B,C
O-2
O-3
RUN
O-4
O-5
O-6
O-7
FU
O-8
SO
O-9
O-10
O-11
O-12
The center LED segments are always ON.
FR-A8AY
The center LED segments are always ON.
FR-A8AR
Via communication
Range
Pr.170 = "9999"
0 to 65535 kWh
(initial value)
- Display example -
When signals STF,
RH and RUN are on
Output terminal
FR-E800-E
A,B,C
SO
Increment
1 kWh
FR-E800-SCE
A,B,C