d.
Slide the tape drive the remaining distance into the library. Use care not to damage the cables during this
step.
4.
Completing the installation—
a.
Attach the SCSI cover plate and the tape drive cover plate that came with your replacement kit. See
Drive Cover Plates" on page 3
!
Important
R
T
EPLACING A
APE
!
Important
To replace a half height tape drive with a full height tape drive, follow these steps.
1.
Preparing for replacement—
a.
Update library firmware to v. V1D181 or higher (see Important note above).
b.
Power off the host.
c.
Power off the library (press the 0 on the back of the unit).
d.
Disconnect the power cord, the SCSI or Fibre Channel cable(s), and the terminator (if present).
e.
Remove the tape drive cover plate. Set the plate and the screws aside.
Figure 15
Tape drive cover plate (HH SCSI library)
and
Figure 14 on page
The library requires both the SCSI cover plates and the tape drive cover plates for
ESD protection. Do not leave any openings uncovered.
D
(H
RIVE
ALF HEIGHT TO
You must update your Magnum 448 library to the current firmware (v. V1D181 or
higher) before you install your new drive. The firmware allows the library to
auto-configure the tape drive installation upon power up, eliminating the step of
manually configuring the library after tape drive installation.
If your library code is not updated to v. V1D181 or higher, you will need to contact
Tandberg Data technical support for manual configuration instructions.
Back of
library
11.
F
)
ULL HEIGHT
"Tape
Screws
(4 each side)
Tape drive
cover plate
Power OFF
0
(press the
)
Disconnect
power cord
13
16
OF
Need help?
Do you have a question about the Magnum 448 and is the answer not in the manual?