Download Print this page

Specifications - Banner SureCross Q45 Quick Start Manual

Wireless sensor-button/light
Hide thumbs Also See for SureCross Q45:

Advertisement

• Connect the red tower light (brown) wire to the Gateway's DO1 terminal.
• Connect the green tower light (black) wire to the Gateway's DO2 terminal.
• Connect the tower light's ground (blue) wire to the Gateway's GND terminal.
On the Wireless Q45 Sensor
To configure the sensor for this call for parts application, use the default DIP switch settings (all set to the OFF position). Verify the
Wireless Q45 is set to be Node 01.

Specifications

The following specifications refer to both the radio and the wireless sensor.
Radio
Radio Range
2.4 GHz: Up to 1000 meters (3280 feet) with line of
sight
Radio Transmit Power
2.4 GHz: 65 mW EIRP
2.4 GHz Compliance
FCC ID UE300DX80-2400 - This device complies with
FCC Part 15, Subpart C, 15.247
ETSI/EN: In accordance with EN 300 328: V1.7.1
(2006-05)
IC: 7044A-DX8024
Spread Spectrum Technology
FHSS (Frequency Hopping Spread Spectrum)
The actual radio range significantly decreases without line of sight.
Always verify your wireless network's range by running a site sur-
vey.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
SureCross Wireless Q45 Sensor - Button/Light
Wireless Q45 Sensor
Typical Battery Life: Two years. A typical battery life assumes an
average of 10 seconds between sensor changes of state and the
default 62.5 millisecond sample rate. Battery life is reduced to one
year with an average of one second between changes of state.
Battery life with light in flashing mode: one year.
Battery life with light in solid mode: one month
Default Sensing Interval: 62.5 milliseconds
Report Rate: On Change of State
Adjustments: Multi-turn sensitivity control (allows precise sensitiv-
ity setting - turn clockwise to increase gain.
Indicators: Red and green LEDs (for radio function); amber LED
(only for alignment mode)
Construction: Molded reinforced thermoplastic polyester housing,
oring-sealed transparent Lexan® cover, molded acrylic lenses,
and stainless steel hardware. Q45s are designed to withstand
1200 psi washdown.
Environmental Rating: NEMA 6P, IEC IP67
Operating Conditions: –40 to +70 °C (–40 to +158 °F); 90% rela-
tive humidity at 50 °C (non-condensing)

Advertisement

loading

This manual is also suitable for:

Dx80n2q45bl-rg