Chapter 4 Se955-I100R/I300R/E100R Specifications; Introduction; Technical Specifications - Motorola SE955 Integration Manual

Table of Contents

Advertisement

CHAPTER 4 SE955-I100R/I300R/E100R

Introduction

This chapter provides the technical specifications of the SE955-I100R, SE955-I300R, and SE955-E100R scan
engines. Decode zone and exit window characteristics are also presented.

Technical Specifications

Technical Specifications @ 23°C
Table 4-1
Item
Power Requirements
Input Voltage
Scanning Current
Continuous Mode Current
(Laser not on)
Standby Current
V
Noise Level
cc
Surge Current
Scan Repetition Rate
Laser Power (at 650 nm)
Optical Resolution
Print Contrast
SPECIFICATIONS
3.0 VDC to 3.6 VDC
86 mA typical / 114 mA max.
45 mA typical / 56 mA max.
12μA typical / 60 μA max
100 mV peak to peak max.
200 mA typical (depending on power supply rise time)
92 min., 104 typical, 116 max. scans/sec (bidirectional)
SE955-I100R/I300R:
1.7 mW (± 0.2 mW) scan mode; 0.5 mW (± 0.05 mW) aim mode
SE955-E100R:
0.7 mW (± 0.1 mW) scan mode; aim mode not supported
0.004 in. minimum element width
minimum 25% absolute dark/light reflectance measured at 650 nm.