Motorola SE955 Integration Manual page 189

Table of Contents

Advertisement

10 - 2 SE955 Integration Guide
Table 10-1
lists all the SSI Opcodes that the SE955 supports. It identifies the SSI partner allowed to send a
message of each type. The host transmits type H opcodes, the decoder transmits type D opcodes, and either
partner can transmit Host/Decoder (H/D) types.
SSI Commands
Table 10-1
Name
AIM_OFF
AIM_ON
BEEP
CMD_ACK
CMD_NAK
CUSTOM_DEFAULTS
DECODE_DATA
DISABLE ALL SYMBOLOGIES H
EVENT
LED_OFF
LED_ON
PARAM_DEFAULTS
PARAM_REQUEST
PARAM_SEND
REPLY_REVISION
REQUEST_REVISION
SCAN_DISABLE
SCAN_ENABLE
SLEEP
START_DECODE
STOP_DECODE
WAKEUP
Note: D = Decoder, H = Host, H/D = Host/Decoder
Type
Opcode
H
0xC4
Deactivate aim pattern.
H
0xC5
Activate aim pattern.
H
0xE6
Sound the beeper.
H/D
0xD0
Positive acknowledgment of received
packet.
H/D
0xD1
Negative acknowledgment of received
packet.
H
0x12
Write or restore values to custom defaults.
D
0xF3
Decode data in SSI packet format.
0xC9
Disable all symbologies.
D
0xF6
Event indicated by associated event code.
H
0xE8
De-activate LED output.
H
0xE7
Activate LED output.
H
0xC8
Set parameter default values.
H
0xC7
Request values of certain parameters.
H/D
0xC6
Send parameter values.
D
0xA4
Reply to REQ_REV contains decoder's
software/hardware configuration.
H
0xA3
Request the decoder's configuration.
H
0xEA
Prevent the operator from scanning bar
codes.
H
0xE9
Permit bar code scanning.
H
0xEB
Request to place the decoder into low
power.
H
0xE4
Tell decoder to attempt to decode a bar
code.
H
0xE5
Tell decoder to abort a decode attempt.
H
N/A
Wakeup decoder after it's been powered
down.
Description
Page
10-5
10-6
10-8
10-10
10-11
10-13
10-14
10-16
10-17
10-18
10-19
10-20
10-21
10-23
10-25
10-27
10-28
10-29
10-30
10-31
10-32
10-33

Advertisement