CLSI Editing

Parameter # 0x36
When enabled, this parameter strips the start and stop characters and inserts a space after the first, fifth, and
tenth characters of a 14-character Codabar symbol.
NOTE Symbol length does not include start and stop characters.

NOTIS Editing

Parameter # 0x37
When enabled, this parameter strips the start and stop characters from decoded Codabar symbol.
Enable CLSI Editing
(0x01)
*Disable CLSI Editing
(0x00)
Enable NOTIS Editing
(0x01)
*Disable NOTIS Editing
(0x00)