Appendix A - Troubleshooting; Robotics Hangs; Lost Contact With Slave Unit; Library Unit Fails To Get Cartridge From Hra - Overland Storage NEO 8000e Manual

Tape library
Hide thumbs Also See for NEO 8000e:
Table of Contents

Advertisement

Appendix A
This appendix provides some solutions to possible problems that might be encountered
using a NEO 8000e library system with an HRA installed. If necessary, contact Overland
Storage Technical Support (see the "Preface").

Robotics Hangs

While moving cartridges between library units, the library robotics hang.
Possible Cause
The library system is not level.
Defective robotics.

Lost Contact with Slave Unit

During system operations, the Master unit loses contact with the Slave unit. This can result
in tape cartridges being "orphaned" in the Slave unit.
Possible Cause
Firmware not updated to version
4.05 or higher.

Library Unit Fails to Get Cartridge from HRA

Either the Master or Slave unit's shuttle fails to take the tape cartridge from the HRA
shuttle.
Possible Cause
The HRA is not properly fastened
to the Mounting Brackets causing
it to be tilted.
104370-004 12/2012
Troubleshooting
Suggested Resolution
Re-level the entire library system both front-to-back and side-to-side.
Refer to
Chapter 4, "Connect the Libraries"
Contact Overland Storage Technical Support to order a new part.
Suggested Resolution
Download and update the firmware.
Suggested Resolution
• Verify that the screws securing the Mounting Brackets to the
libraries are properly tightened. Also verify that the screws
securing the HRA to the Mounting Brackets are tight.
• Verify that the library system is level.
©2005-12 Overland Storage, Inc.
for details.
A-1

Advertisement

Table of Contents
loading

Table of Contents