Introduction / Table of Contents
®
EchoWave
utilizes TDR (Time Domain Reflectometry) technology. It is best described as low-energy, high-
frequency electromagnetic impulses, generated by the sensor's circuitry that is propagated along the probe as
it is immerged in the liquid to be measured. Impulses hit the surface of the media and part of the impulse
energy is reflected back up the probe to the circuitry. Level Measurement is calculated from the time difference
between the impulses sent and the impulses reflected. The sensor analyzes the level output as a continuous
measurement reading from its analog output. TDR-Sensors are also known as Guided Radars or Guided Wave
Radars (GWR).
NEW FEATURES
Precise continuous level measurement in one device
Complete galvanic insulation of device electronics from its inputs/outputs and the tank potential (no
problems with electrochemical corrosion protection)
Highly robust measurement due to 3-wire design, innovative signal analysis and disturbance signal
suppression
TABLE OF CONTENTS
Introduction: ...................................................................................................................... 2
Specifications: .................................................................................................... 3-4
Dimensions: .......................................................................................................... 5
About this Manual: ................................................................................................ 6
Part Numbers: ....................................................................................................... 8
Probe Length: ....................................................................................................... 9
Measurement Range: ......................................................................................... 12
Installation Tips: ............................................................................................. 17-20
Wiring (Analog Output): .................................................................................................. 21
Configuration: ................................................................................................................. 25
USB Fob Interface: .................................................................................. 27
Step 6 - Write to Unit: .......................................................................................... 32
Empty Signal Scan: ........................................................................................................ 32
Appendix: ........................................................................................................................ 34
Echo Curve: ........................................................................................................ 34
Sensor Configuration: .................................................................................... 35-37
Write to Unit: ....................................................................................................... 42
Cutting the Probe: .......................................................................................... 43-45
Troubleshooting: ................................................................................................ 47
Warranty: ....................................................................................................................... 48
|
2
Step One
MN300840 REV A8