Ratings, Characteristics, and Functions
Item
115 VAC input
Efficiency *
230 VAC input
Voltage range *
Frequency *
115 VAC input
Current *
230 VAC input
Input
Power factor
115 VAC input
Leakage current
230 VAC input
115 VAC input
Inrush current *
(for a cold start at 25°)
230 VAC input
Rated Output Current
Voltage adjustment range *
Ripple & Noise
100 to 240 VAC
voltage *
input
Input variation influence *
Load variation influence *
Output
Temperature vari-
100 to 240 VAC
ation influence
input
115 VAC input
Startup time *
230 VAC input
115 VAC input
Hold time *
230 VAC input
Overload protection
Overvoltage protection *
Overheat protection
Addi-
tional
Series operation
func-
Parallel operation
tions
Remote sensing
Remote control
Output indicator
Withstand voltage
Insula-
tion
Insulation resistance
Ambient operating temperature
Storage temperature
Envi-
Ambient operating humidity
ronment
Vibration resistance
Shock resistance
MTBF
Reliabil-
ity
Life expectancy *
Dimensions (W×H×D)
Con-
Weight
struc-
Cooling fan
tion
Degree of protection
Harmonic current emissions
Conducted Emis-
sions
EMI
Radiated Emis-
sions
EMS
Stan-
dards
Safety Standards
Marine Standards
SEMI
* Refer to Conditions on page 12.
Power rating
Output voltage
5 V
80% typ.
82% typ.
Single phase 85 to 264 VAC, 120 to 370 VDC (The L terminal for the DC input is the positive side and safety
standards do not apply.) (Derating is required according to the input voltage. Refer to Derating Curves on
page 18.)
50 /60 Hz (47 to 450 Hz)
0.3 A typ.
0.19 A typ.
---
0.05 mA
0.10 mA
16 A typ.
32 A typ.
3 A
−10% to 10% (with V. ADJ)
30 mVp-p max.
0.5% max.
1.0% max.
0.03%/°C max.
490 ms typ.
470 ms typ.
14 ms typ.
83 ms typ.
Yes, automatic reset
Yes, 115% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input
again)
No
Yes (For up to 2 Power Supplies, external diodes are required.)
No (However, backup operation is possible, external diodes are required.)
No
No
Yes (LED: Green)
3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA
2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA
1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA
100 MΩ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC
−20 to 60°C (Derating is required according to the temperature. Refer to Derating Curves on page 17.) (with
no condensation or icing)
−40 to 85°C (with no condensation or icing)
20% to 90% (Storage humidity: 10% to 95%)
10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Z directions
10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Z directions
, 3 times each in ±X, ±Y, ±Z directions
150 m/s
2
135,000 hrs min.
10 years min.
Refer to Dimensions on page 23.
150 g max.
No
---
Conforms to EN 61000-3-2, GB17625.1
Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254
Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254
Conforms to EN 61204-3 high severity levels
Approved Standards
UL : cURus UL 60950-1 (Recognition) OVC II Pol2
CSA: cURus C22.2 No60950-1
CCC: GB4943
Conformed Standards
EN: EN 60950-1 OVC II Pol2
No
No
15 W
12 V
84% typ.
84% typ.
85% typ.
86% typ.
0.05 mA
0.05 mA
0.10 mA
0.10 mA
1.3 A
1 A
30 mVp-p max.
40 mVp-p max.
500 ms typ.
470 ms typ.
480 ms typ.
450 ms typ.
16 ms typ.
18 ms typ.
87 ms typ.
92 ms typ.
S8FS-C
15 V
24 V
85% typ.
87% typ.
0.05 mA
0.10 mA
0.7 A
30 mVp-p max.
480 ms typ.
460 ms typ.
15 ms typ.
79 ms typ.
3