Mounting
The standard mounting pattern is shown below.
Mounting Pattern A
*1
20 mm min .
The above figure shows a model with the terminal block facing
upward.
Mounting Pattern B
*1
20 mm min .
The above figure shows a model with the terminal block facing
upward.
Mounting Pattern C *2
*1
*1
20 mm min .
The above figure shows a model with the terminal block facing
forward.
Mounting Pattern D *2
*1
S8FS-C@@@@
20 mm min .
To mount the Power Supply to a DIN Rail,
hook portion (A) of the Power Supply onto the
DIN Rail and press the Power Supply in
direction (B) until you hear it lock into place.
Make sure that the catch on the Mounting
Bracket is engaged with the DIN Rail.
To dismount the Power Supply, pull down
portion (C) with a flat-blade screwdriver and
pull out the Power Supply.
*1. Air flow
*2. For mounting patterns C and D, a
separately sold Mounting Bracket is
used to mount the Power Supplies to
DIN Rail. Refer to Mounting Brackets
(Order Separately) on page 29 for the
separately sold Mounting Brackets.
*1
75 mm min.
*1 75 mm min.
75 mm min.
*1
75 mm min .
S8FS-C@@@@J
20 mm min .
(A)
(B)
(C)
Rail stopper
Wiring
• Connect the ground completely.
A protective earthing terminal stipulated in safety standards is
used. Electric shock or malfunction may occur if the ground is not
connected completely.
• Minor fire may possibly occur. Ensure that input and output
terminals are wired correctly.
• Do not apply more than 75 N force to the terminal block when
tightening it.
• Be sure to remove the sheet covering the Power Supply for
machining before power-ON so that it does not interfere with heat
dissipation.
• Use the following material for the wires to be connected to the
S8FS-C to prevent smoking or ignition caused by abnormal loads.
Recommended Wire Gauges
Terminals
Model
S8FS-C015
S8FS-C025 to
S8FS-C100
Input
S8FS-C150 or
S8FS-C200
S8FS-C350
S8FS-C015
S8FS-C02512 to S8FS-C02524
S8FS-C03515 to S8FS-C03524
S8FS-C05024 to S8FS-C05048
S8FS-C02505 or S8FS-C03512
S8FS-C05012 to S8FS-C05015
S8FS-C07515 to S8FS-C07548
Output
S8FS-C10024 to S8FS-C10048
S8FS-C15036 to S8FS-C15048
S8FS-C03505 or S8FS-C05005
S8FS-C07505 to S8FS-C07512
S8FS-C10005 to S8FS-C10015
S8FS-C15005 to S8FS-C15024
S8FS-C200 or
S8FS-C350
S8FS-C015
Protective
earth
S8FS-C025 to
terminal
S8FS-C350
Note: The current capacity for the output terminals on the S8FS-
C025 to S8FS-C350 is 25 A for each terminal.
Make sure to use multiple terminals together if the current flow
is higher than the current capacity for each terminal.
Overload Protection
• If the Power Supply has been short-circuited or supplied with an
overcurrent longer than 10 seconds, the internal parts of the Power
Supply may occasionally deteriorate or be damaged.
• Internal parts may possibly deteriorate or be damaged if the Power
Supply is used for applications with frequent inrush current or
overloading at the load end. Do not use the Power Supply for such
applications.
S8FS-C
Recommended
Wire Gauges
AWG14 to 22
AWG12 to 20
AWG12 to 16
AWG12
AWG14 to 18
AWG12 to 20
AWG12 to 16
AWG12
AWG14
AWG12 to 14