Banner SureCross DX80 FlexPower Manual

Banner SureCross DX80 FlexPower Manual

Thermocouple node
Hide thumbs Also See for SureCross DX80 FlexPower:

Advertisement

Quick Links

SureCross DX80 FlexPower Thermocouple Node
IP20 Base
900 MHz
For additional information, the most recent version of all documentation, and a complete list of accessories, refer to Banner Engineering's
website, www.bannerengineering.com/surecross.
Models
Model
Frequency
DX80N9X2S2N2T
900 MHz ISM Band
DX80N2X2S2N2T
2.4 GHz ISM Band
DX80N9X2S2N2TC
900 MHz ISM Band IP20, NEMA 1
DX80N2X2S2N2TC
2.4 GHz ISM Band
Internal antenna models are also available. For more information, contact your local Banner Engineering Corp. representative.
WARNING: Not To Be Used for Personnel Protection
Never use this product as a sensing device for personnel protection. Doing so could lead to seri-
ous injury or death. This product does NOT include the self-checking redundant circuitry necessary to
allow its use in personnel safety applications. A sensor failure or malfunction can cause either an ener-
gized or de-energized sensor output condition.
P/N 131297 rev. I
The SureCross® wireless system is a radio frequency network with integrated I/O that
can operate in most environments and eliminate the need for wiring runs. Wireless net-
works are formed around a Gateway, which acts as the wireless network master device,
and one or more Nodes.
• Wireless industrial I/O device with up to three configurable thermocouple inputs (de-
faults to J-type), two selectable discrete inputs, and two NMOS discrete outputs
• One thermistor input used for integrated cold junction compensation (CJC)
• FlexPower® power options allows for +10 to 30V dc, solar, and battery power sour-
ces for low power applications.
IP67 Base
2.4 GHz
• DIP switches for user configuration
• Frequency Hopping Spread Spectrum (FHSS) technology and Time Division Multi-
ple Access (TDMA) control architecture ensure reliable data delivery within the unli-
censed Industrial, Scientific, and Medical (ISM) band
• Transceivers provide bidirectional communication between the Gateway and Node,
including fully acknowledged data transmission
• Lost RF links are detected and relevant outputs set to user-defined conditions
• The DX80...C models are certified for use in Class I, Division 2, Group A, B, C, D;
Zone 2 (Category 3G) Hazardous Locations when properly installed in accordance
with the National Electrical Code, the Canadian Electrical Code, or applicable local
codes/regulations (see Specifications)
Environmental Rating
IP67, NEMA 6
Class I, Division 2, Group A, B, C, D Haz-
ardous Locations (see Specifications)
10/12/2012
I/O
Inputs: Three thermocouople, two select-
able discrete, one thermistor input for
CJC
Outputs: Two NMOS sinking discrete
0 131297
3

Advertisement

Table of Contents
loading

Summary of Contents for Banner SureCross DX80 FlexPower

  • Page 1 Zone 2 (Category 3G) Hazardous Locations when properly installed in accordance with the National Electrical Code, the Canadian Electrical Code, or applicable local codes/regulations (see Specifications) For additional information, the most recent version of all documentation, and a complete list of accessories, refer to Banner Engineering's website, www.bannerengineering.com/surecross. Models...
  • Page 2 SureCross DX80 FlexPower Thermocouple Node The SureCross® DX80 Wireless Network The SureCross® DX80 wireless I/O network provides reliable monitoring without the burden of wiring or conduit installation. The Sure- Cross wireless network can operate independently or in conjunction with a host system, PLC, and/or PC software.
  • Page 3: Setting Up Your Wireless Network

    For additional information, including installation and setup, weatherproofing, device menu maps, troubleshooting, and a list of accesso- ries, refer to one of the following product manuals. • SureCross Quick Start Guide: Banner part number 128185 • SureCross Wireless I/O Network Manual: 132607 •...
  • Page 4: Address Mode

    SureCross DX80 FlexPower Thermocouple Node Switches Device Settings Low resolution (1 degree) Discrete sinking inputs OFF* Discrete sourcing inputs Thermocouple, J-Type OFF* OFF* OFF* OFF* Thermocouple, B-Type Thermocouple, C-Type Thermocouple, D-Type Thermocouple, E-Type Thermocouple, G-Type Thermocouple, K-Type Thermocouple, L-Type Thermocouple, M-Type...
  • Page 5: Temperature Units

    SureCross DX80 FlexPower Thermocouple Node Temperature Units Use the DIP switch to specify if the temperature is stored in degrees Fahrenheit or Celsius. The default position is OFF, setting the temperature to Fahrenheit. For Celsius measurements, set this switch to the ON position.
  • Page 6 SureCross DX80 FlexPower Thermocouple Node Terminal Block (IP20) For the DX8x...C models, PWR in the wiring diagram refers to V+ on the wiring board and GND in the wiring diagram refers to V- on the wiring board. DIx. Discrete IN x.
  • Page 7 SureCross DX80 FlexPower Thermocouple Node Wiring Diagram for Thermistor Inputs The thermistor at A4 is used for cold junction compensation. If the ther- mistor is removed, all other analog temperature points will read “alarm.” Thermistor model Number: BWA-THERMISTOR-001. A4− Supported Thermocouple Types The Thermocouple Node supports up to three thermocouple inputs and defaults to the J-type thermocouple.
  • Page 8: Specifications

    SureCross DX80 FlexPower Thermocouple Node Modbus Register Table (High Resolution Mode) Modbus Holding Register I/O Type Units I/O Range Holding Register Terminal Value Block La- bels Gateway Any Node Min. Max. Val- Min. Max. Value (Dec.) (Dec.) 1 + (Node# × 16) Discrete IN 1 2 + (Node# ×...
  • Page 9 SureCross DX80 FlexPower Thermocouple Node Radio General FCC ID TGUDX80 - This device complies with FCC Weight: 0.26 kg (0.57 lbs) Part 15, Subpart C, 15.247 Mounting: #10 or M5 (SS M5 hardware included) IC: 7044A-DX8009 Max. Tightening Torque: 0.56 N·m (5 in·lbf) 2.4 GHz Compliance...
  • Page 10: Antenna Installation

    All specifications published in this document are subject to change. Banner reserves the right to modify the specifications of prod- ucts without notice. Banner Engineering reserves the right to update or change documentation at any time. For the most recent version of any documentation, refer to our website: www.bannerengineering.com.
  • Page 11: Banner Engineering Corp Limited Warranty

    Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period.

This manual is also suitable for:

Dx80n9x2s2n2tDx80n2x2s2n2tDx80n9x2s2n2tcDx80n2x2s2n2tc

Table of Contents