Banner SureCross FlexPower DX80 Series Manual

Configurable node with discrete inputs and discrete nmos outputs
Hide thumbs Also See for SureCross FlexPower DX80 Series:

Advertisement

Quick Links

SureCross DX80 FlexPower Node
Configurable Node with discrete inputs and discrete NMOS outputs
IP67 Base
2.4 GHz
IP20 Base
900 MHz
For additional information, updated documentation, and accessories, refer to Banner Engineering's website,
ing.com/surecross.
Models
Frequency
DX80N9X2S4N4
900 MHz ISM Band
DX80N2X2S4N4
2.4 GHz ISM Band
DX80N9X2S4N4C
900 MHz ISM Band
DX80N2X2S4N4C
2.4 GHz ISM Band
Internal antenna models are also available. For more information, contact your local Banner Engineering Corp. representative.
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to serious
injury or death. This device does not include the self-checking redundant circuitry necessary to allow its
use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-
energized sensor output condition.
SureCross User Configuration Tool
P/N 136328 Rev. F
The SureCross® wireless system is a radio frequency network with integrated I/O that can oper-
ate in most environments and eliminate the need for wiring runs. Wireless networks are formed
around a Gateway, which acts as the wireless network master device, and one or more Nodes.
• Wireless industrial I/O device with four selectable discrete inputs and four NMOS discrete
outputs
• FlexPower® power options allows for +10 to 30V dc, solar, and battery power sources for
low power applications.
• DIP switches for user configuration
• Two switch power outputs provide sensor actuation voltage of 3.6V dc (battery powered) or
4.3V dc (10 to 30V dc powered)
• Frequency Hopping Spread Spectrum (FHSS) technology and Time Division Multiple Access
(TDMA) control architecture ensure reliable data delivery within the unlicensed Industrial, Sci-
entific, and Medical (ISM) band
• Transceivers provide bidirectional communication between the Gateway and Node, including
fully acknowledged data transmission
• Lost RF links are detected and relevant outputs set to user-defined conditions
• The DX80...C models are certified for use in Class I, Division 2, Group A, B, C, D; Zone 2
(Category 3G) Hazardous Locations when properly installed in accordance with the National
Electrical Code, the Canadian Electrical Code, or applicable local codes/regulations (see
Specifications)
Environmental Rating
IP67, NEMA 6
IP20, NEMA 1
Class I, Division 2, Group A, B, C, D Haz-
ardous Locations (see Specifications)
The User Configuration Tool (UCT) offers an easy way to link I/O points in your wire-
less network, view I/O register values graphically, and set system communication pa-
rameters when a host system is not part of the wireless network.
The UCT requires a special USB to RS-485 (model number BWA-UCT-900 for 1 Watt
radios, BWA-HW-006 can be used for all other radios) converter cable to pass infor-
mation between your computer and the Gateway. Download the most recent revi-
sions of the UCT software from Banner Engineering's website:
gineering.com/wireless.
7/18/2013
www.bannerengineer-
I/O
Inputs: Four selectable discrete
Outputs: Four NMOS sinking discrete
http://www.banneren-
0 136328
9

Advertisement

Table of Contents
loading

Summary of Contents for Banner SureCross FlexPower DX80 Series

  • Page 1 2.4 GHz ISM Band ardous Locations (see Specifications) Internal antenna models are also available. For more information, contact your local Banner Engineering Corp. representative. WARNING: Not To Be Used for Personnel Protection Never use this device as a sensing device for personnel protection. Doing so could lead to serious injury or death.
  • Page 2: Setting Up Your Wireless Network

    For additional information, including installation and setup, weatherproofing, device menu maps, troubleshooting, and a list of accesso- ries, refer to one of the following product manuals. • SureCross Quick Start Guide: Banner part number 128185 • SureCross Wireless I/O Network Manual: 132607 •...
  • Page 3 SureCross DX80 FlexPower Node Switches Device Settings Modbus or UCT configured (overrides DIP OFF* switches 3-8) DIP switch configured Inputs sinking (NPN) OFF* Inputs sourcing (PNP) Link loss output: zero OFF* OFF* Link loss output: one Link loss output: hold last state Link loss output: user configuration * Default configuration Address Mode...
  • Page 4 SureCross DX80 FlexPower Node Wire No. Wire Color 10 to 30V dc Powered Nodes Battery Powered Nodes Brown 10 to 30V dc White Blue dc common (GND) dc common (GND) Black Gray 3.6 to 5.5V dc DX80...C Wiring Wiring power to the DX80...C models varies depending the power requirements of the model. Connecting dc power to the communication pins (Tx/Rx) causes permanent damage.
  • Page 5: Modbus Register Table

    SureCross DX80 FlexPower Node FlexPower Discrete Models FlexPower Serial Interface Models FlexPower Counter Models SPx. Switch Power. Provides variable RX/-. Serial comms line for Gateways and SPx. Switch Power. Provides variable power sources for external devices. DX85s only. No connection for Nodes. power sources for external devices.
  • Page 6: Specifications

    SureCross DX80 FlexPower Node I/O # Modbus Holding Register I/O Type I/O Range Holding Register Rep- Terminal resentation Block Labels Gateway Any Node Min. Value Max. Val- Min. Max. (Dec.) (Dec.) 1 + (Node# × 16) Discrete IN 1 2 + (Node# × 16) Discrete IN 2 3 + (Node# ×...
  • Page 7 SureCross DX80 FlexPower Node Radio and General Radio range is with the 2 dB antenna that ships with the product. High-gain antennas are available, but the range depends on the environment and line of sight. To determine the range of your wire- less network, perform a Site Survey.
  • Page 8: Banner Engineering Corp Limited Warranty

    ER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp.