Advertisement

Dimmer Button Double Tap Monitor String
DBDT Monitor String
Syntax
DBDT, <address>, <button number>
Parameter Description
address
system address of the H48 or RF
dimmer/switch
button
button number that was double tapped
number
Description
The DBP monitor string is output from a processor when the tap switch for an H48
dimmer/switch is double tapped. It is output from a processor when the tap switch for an RF
dimmer/switch is double tapped only if the dimmer has keypad-like programming. This string is
not generated when the tap switch for a D48 dimmer/switch is double tapped.
Example
Someone double taps the H48 tap switch on processor 1, link 4, router 1, bus 3, dimmer 2.
DBDT, [01:04:01:03:02], 1
Someone double taps the programmed RF tap switch on processor 1, link 8, dimmer 54. (The
device type is 1 for all RF dimmers/switches.)
DBDT, [01:08:01:54], 1
See Also
DBP Monitor String
DBR Monitor String
DBH Monitor String
KBMON - Keypad button monitoring on
KBMOFF - Keypad button monitoring off