Dimmer Button Press Monitor String
DBP Monitor String
Syntax
DBP, <address>, <button number>
Parameter Description
address
system address of the H48 or RF
dimmer/switch
button
button number that was pressed
number
Description
The DBP monitor string is output from a processor when the tap switch for an H48 or RF
dimmer/switch is pressed. This string is not generated when the tap switch for a D48
dimmer/switch is pressed nor when the raise/lower rocker for any dimmer is pressed.
Example
Someone presses the H48 tap switch on processor 1, link 4, router 1, bus 3, dimmer 2.
DBP, [01:04:01:03:02], 1
Someone presses the RF tap switch on processor 1, link 8, dimmer 54. (The device type is 1
for all RF dimmers/switches.)
DBP, [01:08:01:54], 1
See Also
DBR Monitor String
DBH Monitor String
DBDT Monitor String
KBMON - Keypad button monitoring on
KBMOFF - Keypad button monitoring off
http://www.lutron.com/hwi/Help/l232/dbp_mon.htm [7/3/03 1:19:47 PM]