Chapter 6 Robot Installation; Brief Installation Steps; Important Safety Instructions; Workspace Of The Robot - Elite EC66 User Manual

Hide thumbs Also See for EC66:
Table of Contents

Advertisement

6.1 Brief Installation Steps

The brief installation steps of the EC66 robot:
1. Confirm the workspace of the robot.
2. Install the robot body on the base.
3. Install the end/tool effector.

6.2 Important Safety Instructions

Environmental conditions for installation:
Without corrosive gas or liquid
Without dust or metal powder
Without radioactive material
Without oil mist
Without mechanical shock and vibration
Low humidity
Less than 1000m above sea level
Avoid direct sunshine (prevent the robot from being used outdoors)
Without salt mist
Without electromagnetic noise
Without flammable materials
Ambient temperature: at 0°C ~ 45°C
Operating humidity: 5%~90% (without dewing)
Bearing capacity of the floor: the robot is installed on a hard surface. The surface should be able
to bear at least ten times of the complete torsion of the base joints and at least five times of the
weight of the robot arm. In addition, the surface should be free from vibration. Please refer to the
appendix for the specific bearing capacity. The safety assessment must be implemented upon
completion of each installation of the robot, and the instructions in Part I (Safety) should be strictly
followed.
Description of installation of the additional device: if the additional components, such as the
cable which is outside the rang that Suzhou Elite Robot Co., Ltd. should provide, are integrated into
the industrial robot, it is the user's responsibility to ensure that these components are completely
unaffected and the safety functions would not be affected.

6.3 Workspace of the Robot

6.3.1 Mechanical dimensions of the robot

The mechanical dimensions diagram of the EC66 robot is shown in Figure 6-1. The range of

Chapter 6 Robot Installation

Page 26 of 130
Doc No.:T202001005
www.elibot.cn

Advertisement

Table of Contents
loading