6.3

Maintenance preparation

Make sure that the inlet to the pumping station is not used during maintenance work.
Make sure that the pumping station cannot be switched on accidentally during maintenance work. This
applies in particular if the control unit is in a different room to the system tank.
6.4

Maintenance tasks

6.4.1 Cleaning the pumping station

• Lower the wastewater level in the system tank to a minimum. To do this, switch on the wastewater pump
until the pump draws in air (see 4.6)
• Switch the system off (switch the main switch off or remove the mains plug), secure against being switched
back on again.
Cleaning the wastewater pump
• Remove the wastewater pump; to do this, pull the pump <1>
slowly upwards and out of the chamber by the pump
chain <2>
• Make sure that the wastewater pump intake is free from
suspended matter and solids, clean if necessary.
010-992
Maintenance
58 / 208
1
Ill. [19]
2
2018/07