6.3

Maintenance preparation

Make sure that the inlet to the pumping station is not used during maintenance work.
Make sure that the pumping station cannot be switched on accidentally during maintenance work. This applies in
particular if the control unit is in a different room than the system tank.
6.4

Maintenance tasks

6.4.1

Replace battery

Proceed as described in the operating instructions of the control unit.
6.4.2

Clean the pumping station

Lower the wastewater level in the system tank to a minimum. To do this, switch on the wastewater pump until the
pump draws in air (see 5.6).
Cleaning the wastewater pump
ATTENTION: If the one-handed closure <3> is opened, the water in
the pressure pipe <4> flows out freely.
Open the one-handed closure on the riser; to do this, swing the lever
<3> in the direction of the arrow.
Remove the wastewater pump; to do this, use suitable lifting gear to
pull the pump <2> slowly upwards and out of the chamber.
Make sure that the wastewater pump intake is free from suspended
matter and solids, clean if necessary. In case of stubborn dirt, remove,
clean and re-install.
Cleaning the submersible bell
• Clean the submersible bell <9> so that it is free from adhering dirt
and deposits.
2019/12
Maintenance
44 / 148