Factory settings

DN
Pulse value 1/2
mm
l/puls
25
0.05 / 1
32
0.05 / 1
40
0.1 / 1
50
0.2 / 1
65
0.2 / 1
80
0.5 / 1
100
0.5 / 1
125
1 / 1
150
2 / 10
200
2 / 10
250
5 / 10
300
5 / 10
350
5 / 10
400
10 / 10
450
10 / 10
500
15 / 10
600
20 / 100
650
20 / 100
700
20 / 100
750
30 / 100
800
30 / 100
850
30 / 100
900
30 / 100
1'000
50 / 100
- Low flow cut-off below 0.2 %.
- Analog output 4 - 20 mA equivalent to 0 - 100 % of flow (full scale value).
- Empty pipe detection off.
- Level 2 access code = 111 111.
- Automatic range switching off.
AMFLO
MAG Pro
®
Pulse length
Unit
ms
m
3
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
Full scale value
m
/h (100 %)
3
18
29
46
72
121
184
288
450
648
1'152
1'800
2'592
3'528
4'608
5'832
7'200
10'368
12'168
14'112
16'200
18'432
20'808
23'328
28'800
33

Hide quick links: