Checking The Flow Sensor - INTEGRA Metering AMFLO MAG Pro Mounting And Operating Instructions

Table of Contents

Advertisement

Available languages

Available languages

Menu 10 Diagnostic
(Pos. 10.1) - Automatic self-test [Self test]
This function interrupts the measuring process and performs a self-test for signal evaluation and coil control. To execute the function, press
the key
. Confirm the question 'EXECUTE?' by pressing the key
being aborted. After completion, the result is displayed and normal operation resumes. This function is performed automatically on switching
on the device.
(Pos. 10.2) - Flow simulation [Simulation]
This function simulates a flow and can be used as a function test for connected devices. After activation, the flow rate can be simulated in
the main display ("S" visible in main display):
- Start: Press the key
in the main display
- Adjusting: Enter a percentage value and press
- Finish: Press the key
again to come back to adjusting display, to finish press

Checking the flow sensor

To perform the measurement, the plug-in screw-type terminals must be removed.
Resistance test with ohmmeter:
Exciter coil
Measuring electrode
Measuring electrode
Earthing eletrode (optional)
Exciter coil / mass
Measuring electrodes / mass
Measuring electrodes / exciter coil
Shielding coil cable
Shielding electrode cable
AMFLO
MAG Pro
®
more than one second. Operating a different key leads to the process
more than one second
Measuring points
12 - 13
E1 - 1
E2 - 2
E3 - 3
12 / 13 - 3
1 / 2 - 3
1 / 2 - 12 / 13
11 - 12 / 13 / T2
4 - 1 / 2 / 3 / T2
Resistance
50 - 300
<0.5 Ω
<0.5 Ω
<0.5 Ω
>1999 MΩ
>1999 MΩ
>1999 MΩ
>1999 MΩ
>1999 MΩ
31