Technical Data - INTEGRA Metering AMFLO MAG Pro Mounting And Operating Instructions

Table of Contents

Advertisement

Available languages

Available languages

Technical data

Flow sensor
Sizes
Connections
Connection material
Casing
Electrode assembly
Electrode material
Liquids
Nominal pressure
Vacuum resistance
Protection class
Liner
Liquid temperatures
Ambiant temperature
Min. electrical conductivity
Cable length split version
Approvals
Converter
Configuration interface
Measuring accuracy
Current output
Digital output
Ambient temperature
Protection
Features
Power supply
AMFLO
MAG Pro
®
DN 25 - 1000
Flange (DIN, ANSI, JIS)
Carbon steel lacquered RAL 9006 (optional: stainless steel)
Carbon steel lacquered RAL 9006
2 signal electrodes and 1 ground electrode
AISI 316L (1.4404), optional: Hast-C, titanium, tantalum, platinum
Water, water-glycol mixtures
PN 16, cls 150, JIS 10 k (optional: PN 25 or PN 40)
250 mbar (absolute) at max. 100 °C
IP 67
Standard:
PP up to DN 150, Ebonite from DN 200
High temperature: PTFE
PP 0 °C to 60 °C, Ebonite -5 °C to 80 °C, PTFE -20 °C to 100 °C
(PTFE for remote version up to 130 °C, optional 180 °C)
5° C to 55° C
20 μS/cm
2, 5, 10, 20 m (not exchangeable, please specify before order)
Optional: MID, OIML R49, EN 1434, PTB K7.2 (DN 25 - DN 200)
USB-adapter with software (optional)
±0.4 % (±0.002 m/s below 0.5 m/s)
0/4 - 20 mA (corrspond to 0 - 100 % flow), load 800 Ohm
- Output: max 1250 Hz, 100 mA, 40 VDC / open collector (programmable)
- Status: 100 mA, 40 VDC, open collector (programmable)
5...55 °C
IP 67
- Bidirectional measuring
- Empty pipe detection
- Outputs galvanically isolated to power supply
HV: 100 - 240 VAC, 45 - 66 Hz, 6 W
LV: 18 - 45 VAC, 45 - 66 Hz, 6 W
18 - 45 VDC, 6 W