2. 2. Handling, transport and storage

The manufacturer assumes no responsibility if the following safety instructions and instructions are followed precautionary meas-
ures are not observed:
 
Any changes made to the unit without the prior written consent of the manufacturer will result in the following leads to the
l
immediate expiration of product liability and warranty
 
Installation, operation, maintenance and decommissioning of this device may only be carried out by trained personnel, by
l
qualified specialist personnel who have been instructed by the manufacturer, operator or owner to of the plant authorized.
The specialist must have read and understood all of these operating instructions and the have read and understood the
installation instructions and have understood the instructions contained therein. to the rules of the law
 
Check all connections, settings and technical data of peripheral devices
l
 
Open housing or parts of the housing are completely forbidden
l
 
The specified classifications for mechanical loads (e.g. pressure, temperature, etc.) must be observed. Protection class IP
l
must not be exceeded
 
Only operate the system under the specified ambient conditions and installation positions
l
 
Protect the system against over-voltage. In particular, electrical welding is prevented on the associated equipment
l
 
None of the information contained in this manual or in any other document releases the user from the responsibility for
l
planners assessment of the respective system configuration with regard to functionality and operational safety
 
The local labor and safety laws and regulations must be observed
l
2. 3. Disposal rules for RUBIN® SONIC Smart
This device must not be disposed together with the domestic waste. Please return it to the manufacturer for recycling.
3.

Technical characteristics

3. 1. Metrological data

Nominal diameter / thread
Continuous flow rate
Overload flow rate
Transitional flow rate
Min. flow rate
Starting flow rate
Pressure drop class @ Q
Measuring range
Flange standard
4/13
Warning
The device must not be opened. The battery is permanently installed and cannot be changed.
DN
mm
 
Inches
3
Q
m
/h
3
3
Q
m
/h
4
Q
L/h
2
Q
L/h
1
Q
L/h
START
Δ P
-
3
R
-
-
-
WARNING
50
65
80
1/2
2
2"
3
40
63
63
50
78.75
78.75
0.13
0.2
0.2
0.08
0.13
0.13
0.04
0.065
0.065
ISO ANSI
ISO ANSI
ISO
BSI
BSI
100
125
150
4
5
6
100
160
250
125
200
313
0.32
0.51
0.8
0.2
0.32
0.5
0.1
0.15
0.25
Δ P 16
R 500
ISO ANSI
ISO ANSI
ISO
BSI
BSI
1-320-UM-EN-03
200
8
400
500
1.28
0.8
0.4
ISO
PN16/10

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rubin sonic

Table of Contents