CALIBRATION | SBGUIDANCE | SMARTRAX MD

8 CALIBRATION

For configuring a Smartrax MD machine profile, see
general configuring manual – SBGuidance Auto – CAN
– EN (016-8000-100EN-A). However, some settings in
the CANtool are different. The different parts of
configuring a tractor with SBGuidance Smartrax MD
are described in this chapter.
8.1

CANTOOL

Start the Configurator (by pressing "Shift +
SBGuidance'' in the SBGuidance Loader). Go to
Interfaces > CAN > CANTool to open the CANTool
(Figure 38).
Choose the right Hardware manufacturer (Figure 39),
and see the Table underneath for the correct type per
terminal.
Terminal
Hardware manufacturer
GeoSTAR
SBG
Viper 4
Viper4
Viper 4+
Viper4+
Depending on the cabling and the terminal, choose
the Hardware channel. Press 'Initialize' to get
communication with the CANbus (Figure 39).
Make sure there is communication with the CANbus
(received frames is running and Busload > 0%); see red
rectangles in Figure 39.
Press on ''Initialize''. After initializing the CAN-bus the
busload and received frames will increase. The busload
and received frames are visualized at the bottom side
of the CAN-Tool. Check the cabling if the busload and
received frames do not increase.
Raven Industries Inc.
FIGURE 38 OPEN CAN-TOOL.
FIGURE 39 CANTOOL
PAGINA 36/48 | Installation manual | 016-8000-098EN | Rev. A